  "node": {
    "id": "term:iec-61000-6",
    "type": "Term",
    "label": "IEC 61000-6-2 and 61000-6-4",
    "properties": {
      "id": "iec-61000-6",
      "name": "IEC 61000-6-2 and 61000-6-4",
      "aka": [
        "EN 61000-6-2",
        "EN 61000-6-4",
        "industrial EMC"
      ],
      "section": "topic-standards-stationary",
      "definition": "The IEC generic EMC standards for industrial environments: 61000-6-2 sets immunity to electrostatic discharge, bursts, surges, radiated and conducted RF and voltage dips, and 61000-6-4 limits emissions. They apply when no product-specific EMC standard exists, and battery-operated apparatus in industrial locations is explicitly within their scope.",
      "related": [
        "un-r10",
        "bms",
        "charger",
        "inverter",
        "stationary-storage"
      ],
      "url": "https://lemonergy.com/learn/glossary/iec-61000-6/",
      "mentions": [
        "emc"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:6363",
      "source": "term:iec-61000-6",
      "target": "topic:topic-standards-stationary",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:6364",
      "source": "term:iec-61000-6",
      "target": "term:un-r10",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:6365",
      "source": "term:iec-61000-6",
      "target": "term:bms",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:6366",
      "source": "term:iec-61000-6",
      "target": "term:charger",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:6367",
      "source": "term:iec-61000-6",
      "target": "term:inverter",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:6368",
      "source": "term:iec-61000-6",
      "target": "term:stationary-storage",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/iec-61000-6/emc",
      "source": "term:iec-61000-6",
      "target": "term:emc",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-standards-stationary",
      "type": "Topic",
      "label": "Stationary, industrial and product standards",
      "properties": {
        "id": "topic-standards-stationary",
        "name": "Stationary, industrial and product standards",
        "lede": "Safety and performance standards for portable, industrial and grid batteries, their electronics and their installation.",
        "context": "Match scope to product and installation.",
        "example": "A cell-level test does not establish fire performance or commissioning requirements for a complete installation.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/battery-basics/",
        "lesson_label": "Open battery basics"
      }
    },
    {
      "id": "term:un-r10",
      "type": "Term",
      "label": "UN Regulation No. 10",
      "properties": {
        "id": "un-r10",
        "name": "UN Regulation No. 10",
        "abbr": "R10",
        "aka": [
          "ECE R10",
          "automotive EMC"
        ],
        "section": "topic-standards-vehicle",
        "definition": "The UNECE electromagnetic-compatibility regulation for vehicles and their electronic sub-assemblies. A BMS or charger must show it neither emits interference nor fails under it, including while the vehicle is charging from the grid.",
        "related": [
          "bms",
          "charger",
          "un-r100",
          "onboard-charger"
        ],
        "url": "https://lemonergy.com/learn/glossary/un-r10/",
        "mentions": []
      }
    },
    {
      "id": "term:bms",
      "type": "Term",
      "label": "Battery management system",
      "properties": {
        "id": "bms",
        "name": "Battery management system",
        "abbr": "BMS",
        "section": "topic-pack",
        "definition": "The electronics and software that keep a battery inside its safe window: measuring every cell voltage and many temperatures, estimating SOC and SOH, balancing cells, computing current limits, controlling the contactors and reporting over the vehicle network.",
        "related": [
          "state-of-charge",
          "cell-balancing",
          "state-of-power",
          "cell-supervision-circuit",
          "contactor",
          "can-bus"
        ],
        "lesson": "fundamentals/battery-basics/#cell-module-pack",
        "url": "https://lemonergy.com/learn/glossary/bms/",
        "mentions": [
          "state-of-health",
          "cell-voltage"
        ]
      }
    },
    {
      "id": "term:charger",
      "type": "Term",
      "label": "Charger",
      "properties": {
        "id": "charger",
        "name": "Charger",
        "section": "topic-charging",
        "definition": "The power electronics that convert mains or DC supply into the controlled current and voltage a battery needs. For lithium-ion it runs the CC-CV profile within the limits the BMS communicates, and stops rather than floats when the cell is full.",
        "related": [
          "cc-cv-charging",
          "bms",
          "onboard-charger",
          "dc-fast-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/charger/",
        "mentions": []
      }
    },
    {
      "id": "term:inverter",
      "type": "Term",
      "label": "Inverter",
      "properties": {
        "id": "inverter",
        "name": "Inverter",
        "aka": [
          "power conversion system",
          "PCS"
        ],
        "section": "topic-pack",
        "definition": "The power electronics that turn the battery’s DC into AC for a motor or the grid, and back again for charging. In stationary storage it is called the power conversion system and its rating in kW or MW sets the system’s power independently of the battery’s energy.",
        "related": [
          "pre-charge",
          "dc-dc-converter",
          "stationary-storage",
          "energy-management-system",
          "direct-current",
          "iec-62477-1"
        ],
        "url": "https://lemonergy.com/learn/glossary/inverter/",
        "mentions": []
      }
    },
    {
      "id": "term:stationary-storage",
      "type": "Term",
      "label": "Stationary storage",
      "properties": {
        "id": "stationary-storage",
        "name": "Stationary storage",
        "abbr": "BESS",
        "aka": [
          "battery energy storage system",
          "ESS"
        ],
        "section": "topic-applications",
        "definition": "Batteries installed in a fixed place — a container at a solar farm, a cabinet in a home — to shift energy in time or support the grid. LFP cells dominate because cost per cycle and safety matter more than mass.",
        "related": [
          "lfp",
          "energy-management-system",
          "inverter",
          "energy-arbitrage",
          "long-duration-storage",
          "ul-9540a"
        ],
        "url": "https://lemonergy.com/learn/glossary/stationary-storage/",
        "mentions": []
      }
    },
    {
      "id": "term:emc",
      "type": "Term",
      "label": "Ethyl methyl carbonate",
      "properties": {
        "id": "emc",
        "name": "Ethyl methyl carbonate",
        "abbr": "EMC",
        "section": "topic-electrolytes",
        "definition": "A linear carbonate solvent, the most common co-solvent in commercial electrolytes, balancing viscosity, boiling point and low-temperature performance between DMC and DEC.",
        "related": [
          "carbonate-solvent",
          "dmc",
          "dec",
          "ec"
        ],
        "url": "https://lemonergy.com/learn/glossary/emc/",
        "mentions": []
      }
    }
  ]
}