  "node": {
    "id": "term:float-charging",
    "type": "Term",
    "label": "Float charging",
    "properties": {
      "id": "float-charging",
      "name": "Float charging",
      "section": "topic-charging",
      "definition": "Float charging holds a specified standby voltage to offset self-discharge in batteries designed for continuous maintenance. This differs from applying a fixed trickle current or periodically restarting a charger.",
      "related": [
        "trickle-charge",
        "lead-acid",
        "lead-acid-bulk-absorption-float",
        "charging-strategies"
      ],
      "example": {
        "title": "Worked example",
        "text": "A standby charger holds its float voltage as the maintenance current falls. If a standby load changes, supply current may also change while the voltage control target stays the same."
      },
      "url": "https://lemonergy.com/learn/glossary/float-charging/",
      "mentions": [
        "self-discharge",
        "charger"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:float-charging/topic:topic-charging",
      "source": "term:float-charging",
      "target": "topic:topic-charging",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:float-charging/term:trickle-charge",
      "source": "term:float-charging",
      "target": "term:trickle-charge",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:float-charging/term:lead-acid",
      "source": "term:float-charging",
      "target": "term:lead-acid",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:float-charging/term:lead-acid-bulk-absorption-float",
      "source": "term:float-charging",
      "target": "term:lead-acid-bulk-absorption-float",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:float-charging/term:charging-strategies",
      "source": "term:float-charging",
      "target": "term:charging-strategies",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/float-charging/self-discharge",
      "source": "term:float-charging",
      "target": "term:self-discharge",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/float-charging/charger",
      "source": "term:float-charging",
      "target": "term:charger",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:illustratedBy/term:float-charging/visual:maintenance-profile",
      "source": "term:float-charging",
      "target": "visual:maintenance-profile",
      "type": "illustratedBy",
      "properties": {
        "sourceFile": "visual-pages.json"
      }
    },
    {
      "id": "edge:cites/term:float-charging/reference:trojan-lead-charge",
      "source": "term:float-charging",
      "target": "reference:trojan-lead-charge",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-charging",
      "type": "Topic",
      "label": "Charging and discharging",
      "properties": {
        "id": "topic-charging",
        "name": "Charging and discharging",
        "lede": "How current goes in and comes out, and the limits that stop it.",
        "context": "Separate regulation from availability.",
        "example": "The same CC–CV law can operate overnight or during a short depot stop.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open charging quantities"
      }
    },
    {
      "id": "term:trickle-charge",
      "type": "Term",
      "label": "Trickle charging",
      "properties": {
        "id": "trickle-charge",
        "name": "Trickle charging",
        "aka": [
          "float charge",
          "float charging",
          "trickle charge",
          "Trickle and float charging"
        ],
        "section": "topic-charging",
        "definition": "Trickle charging supplies a small maintenance current for chemistries and cells approved for it. Float charging instead regulates standby voltage. Applying continuous trickle current to ordinary lithium-ion cells is unsuitable.",
        "related": [
          "lead-acid",
          "overcharge",
          "calendar-aging",
          "slow-charging",
          "oxygen-recombination",
          "charging-strategies"
        ],
        "url": "https://lemonergy.com/learn/glossary/trickle-charge/",
        "mentions": [
          "float-charging"
        ]
      }
    },
    {
      "id": "term:lead-acid",
      "type": "Term",
      "label": "Lead–acid battery",
      "properties": {
        "id": "lead-acid",
        "name": "Lead–acid battery",
        "section": "topic-other-chemistries",
        "definition": "The oldest rechargeable chemistry, lead and lead dioxide electrodes in sulfuric acid, at 2 V per cell. Heavy and short-lived in deep cycling but cheap, recyclable and good at cold cranking, it still starts most cars and backs up most telecom sites.",
        "related": [
          "nominal-voltage",
          "recycling",
          "specific-energy"
        ],
        "lesson": "labs/battery-materials-lab/#bml-market",
        "url": "https://lemonergy.com/learn/glossary/lead-acid/",
        "mentions": []
      }
    },
    {
      "id": "term:lead-acid-bulk-absorption-float",
      "type": "Term",
      "label": "Lead–acid bulk, absorption and float charging",
      "properties": {
        "id": "lead-acid-bulk-absorption-float",
        "name": "Lead–acid bulk, absorption and float charging",
        "section": "topic-charging",
        "definition": "A common lead–acid charging sequence uses current-limited bulk charge, a regulated absorption voltage with tapering current, and a lower float voltage for standby service. Product specifications determine whether and how each stage is used.",
        "related": [
          "lead-acid",
          "trickle-charge",
          "equalization-charge",
          "float-charging",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "On a relative voltage plot, identify the higher absorption plateau before the lower float plateau. At the same standby voltage, maintenance current can vary with conditions and battery state."
        },
        "url": "https://lemonergy.com/learn/glossary/lead-acid-bulk-absorption-float/",
        "mentions": []
      }
    },
    {
      "id": "term:charging-strategies",
      "type": "Term",
      "label": "Battery charging strategies",
      "properties": {
        "id": "charging-strategies",
        "name": "Battery charging strategies",
        "section": "topic-charging",
        "definition": "Battery charging strategies define how a charger commands current, voltage or power and how it decides to change stages or stop. Chemistry, temperature, battery state and infrastructure also determine which strategies are applicable.",
        "related": [
          "cc-cv-charging",
          "mscc",
          "adaptive-charging",
          "lead-acid-bulk-absorption-float",
          "battery-test-equipment",
          "testing"
        ],
        "example": {
          "title": "Worked example",
          "text": "Compare a current-limited session, a power-limited session and a stepped current schedule at the same starting state of charge. Look for phase transitions and record the achieved charge separately from the peak current."
        },
        "guide": [
          {
            "title": "Basic electrical profiles",
            "terms": [
              "constant-current",
              "constant-voltage",
              "cc-cv-charging",
              "constant-power-charging",
              "cp-cv",
              "mscc",
              "mscc-cv",
              "ramped-current-charging",
              "taper-charging"
            ]
          },
          {
            "title": "Pulse and feedback profiles",
            "terms": [
              "pulse-charging",
              "reverse-pulse-charging",
              "adaptive-charging",
              "model-predictive-charging",
              "non-linear-voltammetry-charging"
            ]
          },
          {
            "title": "Temperature and charging speed",
            "terms": [
              "temperature-conditioned-charging",
              "preconditioning",
              "slow-charging",
              "fast-charging",
              "xfc",
              "dc-fast-charging",
              "charge-acceptance"
            ]
          },
          {
            "title": "Start, stop and maintenance",
            "terms": [
              "precharge-recharge",
              "target-soc-charging",
              "boost-charging",
              "trickle-charge",
              "float-charging",
              "lead-acid-bulk-absorption-float",
              "equalization-charge",
              "nickel-peak-termination",
              "iu-charging-characteristics",
              "negative-delta-v",
              "dt-dt-termination",
              "charge-termination",
              "refresh-charge",
              "reconditioning"
            ]
          },
          {
            "title": "Vehicle and site strategies",
            "terms": [
              "smart-charging",
              "scheduled-charging",
              "depot-charging",
              "opportunity-charging",
              "split-pack-charging",
              "regenerative-braking"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/charging-strategies/",
        "mentions": [
          "charger"
        ]
      }
    },
    {
      "id": "term:self-discharge",
      "type": "Term",
      "label": "Self-discharge",
      "properties": {
        "id": "self-discharge",
        "name": "Self-discharge",
        "section": "topic-charging",
        "definition": "The slow loss of stored charge while a cell is not in use. An unexpected rise can signal a leakage path or a soft internal short.",
        "unit": "%/month",
        "related": [
          "internal-short-circuit",
          "calendar-aging",
          "k-value",
          "calendar-life",
          "self-discharge-test"
        ],
        "lesson": "fundamentals/battery-aging/#check-yourself",
        "url": "https://lemonergy.com/learn/glossary/self-discharge/",
        "mentions": [
          "electrolyte-leakage"
        ]
      }
    },
    {
      "id": "term:charger",
      "type": "Term",
      "label": "Charger",
      "properties": {
        "id": "charger",
        "name": "Charger",
        "section": "topic-charging",
        "definition": "The power electronics that convert mains or DC supply into the controlled current and voltage a battery needs. For lithium-ion it runs the CC-CV profile within the limits the BMS communicates, and stops rather than floats when the cell is full.",
        "related": [
          "cc-cv-charging",
          "bms",
          "onboard-charger",
          "dc-fast-charging"
        ],
        "url": "https://lemonergy.com/learn/glossary/charger/",
        "mentions": []
      }
    },
    {
      "id": "visual:maintenance-profile",
      "type": "Visual",
      "label": "Trickle current and regulated float",
      "properties": {
        "title": "Trickle current and regulated float",
        "summary": "A charger can hold current or hold voltage. The control variable distinguishes these maintenance methods.",
        "readout": "The dashed float voltage stays level while its current changes. The trickle example holds current instead.",
        "formula": "Trickle regulates a small current; float regulates standby voltage.",
        "note": "Original normalized teaching traces. They omit cell calibration and do not specify charger settings or predict charge time, aging or safety.",
        "software": {
          "status": "reference",
          "label": "Reference concept",
          "body": "The article links any separately verified Lemonergy workflow. These curves are independent teaching examples.",
          "href": "../glossary/charging-strategies/"
        },
        "html": "<figure class=\"visual-figure\"><figcaption>Maintenance current</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-maintenance-profile-0-title static-maintenance-profile-0-desc\"><title id=\"static-maintenance-profile-0-title\">Maintenance current</title><desc id=\"static-maintenance-profile-0-desc\">Relative elapsed time versus Relative current. Trickle current; Illustrative float current. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.25</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.5</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.75</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,202.36 342.00,202.36\"/><polyline fill=\"none\" stroke=\"#6953a8\" stroke-width=\"2.8\" stroke-dasharray=\"7 4\" points=\"74.00,133.06 76.68,137.70 79.36,142.10 82.04,146.30 84.72,150.29 87.40,154.08 90.08,157.69 92.76,161.13 95.44,164.39 98.12,167.50 100.80,170.46 103.48,173.27 106.16,175.94 108.84,178.48 111.52,180.90 114.20,183.21 116.88,185.40 119.56,187.48 122.24,189.46 124.92,191.34 127.60,193.14 130.28,194.84 132.96,196.46 135.64,198.01 138.32,199.47 141.00,200.87 143.68,202.20 146.36,203.46 149.04,204.66 151.72,205.81 154.40,206.89 157.08,207.93 159.76,208.91 162.44,209.85 165.12,210.74 167.80,211.58 170.48,212.39 173.16,213.16 175.84,213.88 178.52,214.58 181.20,215.24 183.88,215.87 186.56,216.46 189.24,217.03 191.92,217.57 194.60,218.08 197.28,218.57 199.96,219.04 202.64,219.48 205.32,219.90 208.00,220.30 210.68,220.68 213.36,221.04 216.04,221.39 218.72,221.71 221.40,222.02 224.08,222.32 226.76,222.60 229.44,222.87 232.12,223.13 234.80,223.37 237.48,223.60 240.16,223.82 242.84,224.03 245.52,224.23 248.20,224.41 250.88,224.59 253.56,224.77 256.24,224.93 258.92,225.08 261.60,225.23 264.28,225.37 266.96,225.50 269.64,225.63 272.32,225.75 275.00,225.86 277.68,225.97 280.36,226.08 283.04,226.18 285.72,226.27 288.40,226.36 291.08,226.44 293.76,226.52 296.44,226.60 299.12,226.67 301.80,226.74 304.48,226.81 307.16,226.87 309.84,226.93 312.52,226.99 315.20,227.04 317.88,227.10 320.56,227.14 323.24,227.19 325.92,227.24 328.60,227.28 331.28,227.32 333.96,227.36 336.64,227.39 339.32,227.43 342.00,227.46\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative current</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Trickle current</span><span><i style=\"background:#6953a8\"></i>Illustrative float current (dashed)</span></div></figure>\n<figure class=\"visual-figure\"><figcaption>Maintenance voltage</figcaption><svg class=\"visual-chart\" viewBox=\"0 0 360 330\" role=\"img\" aria-labelledby=\"static-maintenance-profile-1-title static-maintenance-profile-1-desc\"><title id=\"static-maintenance-profile-1-title\">Maintenance voltage</title><desc id=\"static-maintenance-profile-1-desc\">Relative elapsed time versus Relative voltage. Illustrative trickle terminal response; Float voltage setpoint. Interpretation follows the graphs.</desc><path d=\"M74,238h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"242\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0</text><text x=\"74\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0</text><path d=\"M74,188.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"192.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.25</text><text x=\"141\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.25</text><path d=\"M74,139h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"143\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.5</text><text x=\"208\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.5</text><path d=\"M74,89.5h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"93.5\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">0.75</text><text x=\"275\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">0.75</text><path d=\"M74,40h268\" stroke=\"currentColor\" opacity=\".13\"/><text x=\"64\" y=\"44\" text-anchor=\"end\" font-size=\"13\" fill=\"currentColor\">1</text><text x=\"342\" y=\"265\" text-anchor=\"middle\" font-size=\"13\" fill=\"currentColor\">1</text><path d=\"M74,40v198h268\" fill=\"none\" stroke=\"currentColor\" opacity=\".3\"/><polyline fill=\"none\" stroke=\"#2459a8\" stroke-width=\"2.8\" points=\"74.00,129.10 181.20,111.28 342.00,103.36\"/><polyline fill=\"none\" stroke=\"#6953a8\" stroke-width=\"2.8\" stroke-dasharray=\"7 4\" points=\"74.00,89.50 342.00,89.50\"/><text transform=\"translate(208 303)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative elapsed time</tspan></text><text transform=\"translate(20 139) rotate(-90)\" text-anchor=\"middle\" font-size=\"14\" fill=\"currentColor\"><tspan x=\"0\" dy=\"0\">Relative voltage</tspan></text></svg><div class=\"visual-legend\"><span><i style=\"background:#2459a8\"></i>Illustrative trickle terminal response</span><span><i style=\"background:#6953a8\"></i>Float voltage setpoint (dashed)</span></div></figure>"
      }
    },
    {
      "id": "reference:trojan-lead-charge",
      "type": "Reference",
      "label": "Battery maintenance and charging",
      "properties": {
        "title": "Battery maintenance and charging",
        "publisher": "Trojan Battery",
        "url": "https://www.trojanbattery.com/resources/battery-maintenance",
        "type": "Manufacturer technical documentation",
        "scope": "Bulk, absorption, float and product-specific equalization in lead–acid batteries.",
        "accessed": "2026-11-18"
      }
    }
  ]
}