  "node": {
    "id": "term:encapsulation",
    "type": "Term",
    "label": "Encapsulation",
    "properties": {
      "id": "encapsulation",
      "name": "Encapsulation",
      "aka": [
        "overmoulding",
        "low-pressure moulding",
        "cast encapsulation"
      ],
      "section": "topic-pack",
      "definition": "Casting resin around a pack or circuit in a mould that is removed once the resin cures, so that the cured resin itself becomes the outer case. Unlike potting, which fills a housing that stays, it needs no separate enclosure; casting under vacuum removes air voids. Both seal against water and vibration, and both make a pack hard to repair or recycle.",
      "related": [
        "potting-compound",
        "enclosure",
        "ip-rating",
        "intrinsic-safety"
      ],
      "url": "https://lemonergy.com/learn/glossary/encapsulation/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:encapsulation/topic:topic-pack",
      "source": "term:encapsulation",
      "target": "topic:topic-pack",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:encapsulation/term:potting-compound",
      "source": "term:encapsulation",
      "target": "term:potting-compound",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:encapsulation/term:enclosure",
      "source": "term:encapsulation",
      "target": "term:enclosure",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:encapsulation/term:ip-rating",
      "source": "term:encapsulation",
      "target": "term:ip-rating",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:encapsulation/term:intrinsic-safety",
      "source": "term:encapsulation",
      "target": "term:intrinsic-safety",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-pack",
      "type": "Topic",
      "label": "Modules, packs and battery management",
      "properties": {
        "id": "topic-pack",
        "name": "Modules, packs and battery management",
        "lede": "From a single cell to a working battery system, and the electronics that keep it safe.",
        "context": "Make series/parallel architecture explicit.",
        "example": "Twelve 3.6 V, 5 Ah cells in 6s2p give 21.6 V, 10 Ah and 216 Wh nominally before other restrictions.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/cell-architecture/",
        "lesson_label": "Open cell architecture"
      }
    },
    {
      "id": "term:potting-compound",
      "type": "Term",
      "label": "Potting compound",
      "properties": {
        "id": "potting-compound",
        "name": "Potting compound",
        "aka": [
          "potting",
          "encapsulant"
        ],
        "section": "topic-pack",
        "definition": "A liquid resin — polyurethane, silicone or epoxy, sometimes foamed — poured around cells or electronics and cured into a solid block. It fixes cells against vibration, insulates them and can slow thermal propagation; some structural packs fill every gap between cylindrical cells with it. The cost is mass and a pack that is hard to repair or recycle.",
        "related": [
          "structural-adhesive",
          "thermal-propagation",
          "design-for-recycling",
          "dismantling",
          "vibration-test",
          "conformal-coating"
        ],
        "url": "https://lemonergy.com/learn/glossary/potting-compound/",
        "mentions": []
      }
    },
    {
      "id": "term:enclosure",
      "type": "Term",
      "label": "Enclosure",
      "properties": {
        "id": "enclosure",
        "name": "Enclosure",
        "aka": [
          "battery housing",
          "battery tray"
        ],
        "section": "topic-pack",
        "definition": "The sealed case that carries the modules, protects them in a crash, keeps water out to an IP67 rating or better and vents gas in a thermal event. In many cars it is a structural part of the body.",
        "related": [
          "pack",
          "ip-rating",
          "cell-to-chassis",
          "venting",
          "gigacasting",
          "ul-94"
        ],
        "url": "https://lemonergy.com/learn/glossary/enclosure/",
        "mentions": []
      }
    },
    {
      "id": "term:ip-rating",
      "type": "Term",
      "label": "IP rating",
      "properties": {
        "id": "ip-rating",
        "name": "IP rating",
        "aka": [
          "ingress protection"
        ],
        "section": "topic-pack",
        "definition": "A two-digit code for how well an enclosure keeps out solids and water: the first digit for dust, the second for water. Battery packs are typically IP67, dust-tight and able to survive brief immersion.",
        "related": [
          "enclosure",
          "pack",
          "immersion-test"
        ],
        "url": "https://lemonergy.com/learn/glossary/ip-rating/",
        "mentions": []
      }
    },
    {
      "id": "term:intrinsic-safety",
      "type": "Term",
      "label": "Intrinsic safety",
      "properties": {
        "id": "intrinsic-safety",
        "name": "Intrinsic safety",
        "aka": [
          "intrinsically safe battery",
          "Ex i",
          "Ex ia",
          "IEC 60079-11"
        ],
        "section": "topic-safety",
        "definition": "Protection of equipment used in explosive gas or dust by limiting electrical and thermal energy, so that neither a spark nor a hot surface can ignite the atmosphere even with faults present. Under IEC 60079-11, Ex ia tolerates two faults and is allowed in Zone 0. The battery is the hardest part: its short-circuit current and surface temperature must stay below ignition limits.",
        "related": [
          "atex-iecex",
          "encapsulation",
          "short-circuit-test",
          "lithium-thionyl-chloride"
        ],
        "url": "https://lemonergy.com/learn/glossary/intrinsic-safety/",
        "mentions": []
      }
    }
  ]
}