      "definition": "A programmable electronic load sinks current from a powered device. It can hold current, resistance or power within its operating range and may generate repeatable discharge pulses.",
      "related": [
        "bidirectional-dc-supply",
        "capacity-test",
        "pulse-test",
        "battery-test-equipment"
      ],
      "example": {
        "title": "Worked example",
        "text": "A constant-power discharge asks for more current as voltage falls. Compare measured current with the instrument limit and retain any samples where the commanded power could not be reached."
      },
      "url": "https://lemonergy.com/learn/glossary/electronic-load/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:electronic-load/topic:topic-testing-equipment",
      "source": "term:electronic-load",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:electronic-load/term:bidirectional-dc-supply",
      "source": "term:electronic-load",
      "target": "term:bidirectional-dc-supply",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:electronic-load/term:capacity-test",
      "source": "term:electronic-load",
      "target": "term:capacity-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:electronic-load/term:pulse-test",
      "source": "term:electronic-load",
      "target": "term:pulse-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:electronic-load/term:battery-test-equipment",
      "source": "term:electronic-load",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:electronic-load/reference:inl-ev-tests",
      "source": "term:electronic-load",
      "target": "reference:inl-ev-tests",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:bidirectional-dc-supply",
      "type": "Term",
      "label": "Bidirectional DC power supply",
      "properties": {
        "id": "bidirectional-dc-supply",
        "name": "Bidirectional DC power supply",
        "section": "topic-testing-equipment",
        "definition": "A bidirectional DC supply sources current to charge a specimen and sinks current during discharge. A regenerative model can return absorbed energy to its approved power system.",
        "related": [
          "cycler",
          "electronic-load",
          "hppc",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "In a single pack drive-cycle trace, check that the commanded sign changes between charge and discharge, and that the instrument records the measured current at each transition."
        },
        "url": "https://lemonergy.com/learn/glossary/bidirectional-dc-supply/",
        "mentions": []
      }
    },
    {
      "id": "term:capacity-test",
      "type": "Term",
      "label": "Capacity test",
      "properties": {
        "id": "capacity-test",
        "name": "Capacity test",
        "section": "topic-testing",
        "definition": "A defined capacity test with specified charge, rest, discharge and cutoff conditions, usually a full CC-CV charge, a rest, and a C/3 or lower discharge to the lower cutoff at 25 °C. The delivered ampere-hours are the cell’s measured capacity.",
        "related": [
          "nominal-capacity",
          "cc-cv-charging",
          "cutoff-voltage",
          "reference-performance-test",
          "rate-test",
          "cycler"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#nominal-capacity",
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Report delivered ampere-hours and watt-hours with the discharge current, temperature, cutoff and initial charge state."
        },
        "procedure": {
          "equipment": [
            "cycler",
            "battery-test-chamber",
            "battery-cell-fixture"
          ],
          "steps": [
            "Condition the specimen and establish the specified starting charge under the approved procedure.",
            "Record a controlled discharge from the defined starting point to the method's cutoff.",
            "Integrate current for delivered charge and voltage times current for delivered energy."
          ],
          "record": "Report delivered ampere-hours and watt-hours with the discharge current, temperature, cutoff and initial charge state."
        },
        "url": "https://lemonergy.com/learn/glossary/capacity-test/",
        "mentions": []
      }
    },
    {
      "id": "term:pulse-test",
      "type": "Term",
      "label": "Pulse test",
      "properties": {
        "id": "pulse-test",
        "name": "Pulse test",
        "aka": [
          "current pulse test",
          "DC pulse"
        ],
        "section": "topic-testing",
        "definition": "Applying a current step of defined size and duration and recording the voltage response. The instant voltage step gives the ohmic resistance, the following curve the slower polarization; HPPC is a standardised sequence of such pulses across state of charge.",
        "related": [
          "hppc",
          "dcir",
          "internal-resistance",
          "relaxation",
          "equivalent-circuit-model",
          "cycler"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Report current, voltage, sample rate, pulse width, sampling window, temperature and direction. A pulse resistance without a measurement time is ambiguous."
        },
        "procedure": {
          "equipment": [
            "cycler",
            "bidirectional-dc-supply",
            "battery-data-acquisition"
          ],
          "steps": [
            "Stabilize SOC and temperature and record a pre-pulse baseline.",
            "Apply the approved current waveform and time-align current and voltage including the initial edge.",
            "Monitor relaxation and evaluate the voltage change at the declared elapsed time."
          ],
          "record": "Report current, voltage, sample rate, pulse width, sampling window, temperature and direction. A pulse resistance without a measurement time is ambiguous."
        },
        "url": "https://lemonergy.com/learn/glossary/pulse-test/",
        "mentions": [
          "polarization",
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "reference:inl-ev-tests",
      "type": "Reference",
      "label": "Battery Test Manual For Electric Vehicles, Revision 3",
      "properties": {
        "title": "Battery Test Manual For Electric Vehicles, Revision 3",
        "publisher": "Idaho National Laboratory",
        "url": "https://www.osti.gov/servlets/purl/1186745",
        "type": "Test manual",
        "scope": "Performance characterization, pulse resistance/power, life testing and reference performance tests; historical 2015 edition.",
        "year": 2015,
        "authors": [
          "Jon P. Christopherson"
        ],
        "accessed": "2026-10-27"
      }
    }
  ]
}