  "node": {
    "id": "term:dielectric-withstand-tester",
    "type": "Term",
    "label": "Dielectric-withstand tester",
    "properties": {
      "id": "dielectric-withstand-tester",
      "name": "Dielectric-withstand tester",
      "section": "topic-testing-equipment",
      "definition": "A dielectric-withstand tester applies a specified electrical stress to an insulation barrier and monitors leakage or breakdown. A high-voltage safety procedure defines the limits and precautions for the assembly.",
      "related": [
        "dielectric-withstand-test",
        "insulation-resistance-tester",
        "insulation-test",
        "battery-test-equipment"
      ],
      "example": {
        "title": "Worked example",
        "text": "An accredited lab records the tested barrier, test mode and observed leakage against its own approved limits, alongside the instrument identifier and the specimen's test history."
      },
      "url": "https://lemonergy.com/learn/glossary/dielectric-withstand-tester/",
      "mentions": [
        "electrolyte-leakage"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:dielectric-withstand-tester/topic:topic-testing-equipment",
      "source": "term:dielectric-withstand-tester",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:dielectric-withstand-tester/term:dielectric-withstand-test",
      "source": "term:dielectric-withstand-tester",
      "target": "term:dielectric-withstand-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:dielectric-withstand-tester/term:insulation-resistance-tester",
      "source": "term:dielectric-withstand-tester",
      "target": "term:insulation-resistance-tester",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:dielectric-withstand-tester/term:insulation-test",
      "source": "term:dielectric-withstand-tester",
      "target": "term:insulation-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:dielectric-withstand-tester/term:battery-test-equipment",
      "source": "term:dielectric-withstand-tester",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/dielectric-withstand-tester/electrolyte-leakage",
      "source": "term:dielectric-withstand-tester",
      "target": "term:electrolyte-leakage",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:dielectric-withstand-tester/reference:sandia-abuse-manual",
      "source": "term:dielectric-withstand-tester",
      "target": "reference:sandia-abuse-manual",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:dielectric-withstand-test",
      "type": "Term",
      "label": "Battery dielectric withstand test",
      "properties": {
        "id": "dielectric-withstand-test",
        "name": "Battery dielectric withstand test",
        "section": "topic-testing",
        "definition": "A dielectric withstand test verifies that a designated insulation barrier survives a specified electrical stress. It is separate from measuring insulation resistance at a diagnostic test voltage.",
        "related": [
          "dielectric-withstand-tester",
          "battery-data-acquisition",
          "testing"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Report the barrier, test mode, traceable instrument, leakage or breakdown observation and acceptance result under the applicable method."
        },
        "procedure": {
          "equipment": [
            "dielectric-withstand-tester",
            "battery-data-acquisition"
          ],
          "steps": [
            "Identify the insulation barrier and the governing procedure with the qualified lab.",
            "The lab applies the specified electrical stress and monitors the allowed response.",
            "Preserve traceability to the specimen and acceptance criteria."
          ],
          "record": "Report the barrier, test mode, traceable instrument, leakage or breakdown observation and acceptance result under the applicable method."
        },
        "notes": [
          "High-voltage test settings come from the applicable method and qualified lab."
        ],
        "url": "https://lemonergy.com/learn/glossary/dielectric-withstand-test/",
        "mentions": [
          "insulation-resistance"
        ]
      }
    },
    {
      "id": "term:insulation-resistance-tester",
      "type": "Term",
      "label": "Insulation resistance tester",
      "properties": {
        "id": "insulation-resistance-tester",
        "name": "Insulation resistance tester",
        "section": "topic-testing-equipment",
        "definition": "An insulation resistance tester measures leakage under a designated DC test voltage and reports the equivalent insulation resistance. It serves a different purpose from a dielectric-withstand tester.",
        "related": [
          "insulation-test",
          "dielectric-withstand-tester",
          "insulation-resistance",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "After an approved environmental exposure, compare the isolation reading at the same defined connection points and recorded conditions. A change may warrant investigation even when the pack can still deliver power."
        },
        "url": "https://lemonergy.com/learn/glossary/insulation-resistance-tester/",
        "mentions": [
          "electrolyte-leakage"
        ]
      }
    },
    {
      "id": "term:insulation-test",
      "type": "Term",
      "label": "Insulation resistance test",
      "properties": {
        "id": "insulation-test",
        "name": "Insulation resistance test",
        "aka": [
          "hipot test",
          "dielectric strength test"
        ],
        "section": "topic-testing",
        "definition": "Applying a high DC or AC voltage between the high-voltage circuit and the chassis or housing to verify that insulation holds, with the leakage current below a limit. It is done on every pack at end of line and after abuse tests in R100.",
        "related": [
          "insulation-resistance",
          "un-r100-part-2",
          "high-voltage-interlock",
          "end-of-line-testing",
          "insulation-resistance-tester",
          "battery-data-acquisition"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Record the test points, declared instrument settings, insulation resistance and environmental conditions for each measured path."
        },
        "procedure": {
          "equipment": [
            "insulation-resistance-tester",
            "battery-data-acquisition"
          ],
          "steps": [
            "Have the qualified team identify the test boundary and isolation state.",
            "Use the governing procedure to measure the specified insulation paths.",
            "Document restoration of the tested assembly under the approved workflow."
          ],
          "record": "Record the test points, declared instrument settings, insulation resistance and environmental conditions for each measured path."
        },
        "notes": [
          "Pack isolation testing requires the applicable electrical safety procedure and qualified personnel."
        ],
        "url": "https://lemonergy.com/learn/glossary/insulation-test/",
        "mentions": [
          "un-r100",
          "electrolyte-leakage"
        ]
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "term:electrolyte-leakage",
      "type": "Term",
      "label": "Electrolyte leakage",
      "properties": {
        "id": "electrolyte-leakage",
        "name": "Electrolyte leakage",
        "aka": [
          "leakage",
          "mass loss",
          "battery leakage",
          "creep leakage"
        ],
        "section": "topic-safety",
        "definition": "Escape of electrolyte from a cell through a seal, vent or damaged case. Alkaline cells leak corrosive potassium hydroxide, especially when exhausted or reverse-charged, while lithium-ion cells leak flammable solvent. UN 38.3 judges it by visible leakage and by mass loss, allowing 0.1–0.5 % depending on the cell’s mass.",
        "related": [
          "vent",
          "transport-regulations",
          "alkaline-cell",
          "electrolyte",
          "altitude-simulation-test"
        ],
        "url": "https://lemonergy.com/learn/glossary/electrolyte-leakage/",
        "mentions": []
      }
    },
    {
      "id": "reference:sandia-abuse-manual",
      "type": "Reference",
      "label": "USABC Battery Abuse Testing Manual for Electric and Hybrid Vehicle Applications",
      "properties": {
        "title": "USABC Battery Abuse Testing Manual for Electric and Hybrid Vehicle Applications",
        "publisher": "Sandia National Laboratories",
        "url": "https://doi.org/10.2172/1838583",
        "type": "Test manual",
        "scope": "Electrical, thermal and mechanical abuse-test categories and reported observations.",
        "accessed": "2026-11-18"
      }
    }
  ]
}