  "node": {
    "id": "term:dielectric-withstand-test",
    "type": "Term",
    "label": "Battery dielectric withstand test",
    "properties": {
      "id": "dielectric-withstand-test",
      "name": "Battery dielectric withstand test",
      "section": "topic-testing",
      "definition": "A dielectric withstand test verifies that a designated insulation barrier survives a specified electrical stress. It is separate from measuring insulation resistance at a diagnostic test voltage.",
      "related": [
        "dielectric-withstand-tester",
        "battery-data-acquisition",
        "testing"
      ],
      "example": {
        "title": "What the report shows",
        "text": "The test record connects the specimen and conditions to the observation. Report the barrier, test mode, traceable instrument, leakage or breakdown observation and acceptance result under the applicable method."
      },
      "procedure": {
        "equipment": [
          "dielectric-withstand-tester",
          "battery-data-acquisition"
        ],
        "steps": [
          "Identify the insulation barrier and the governing procedure with the qualified lab.",
          "The lab applies the specified electrical stress and monitors the allowed response.",
          "Preserve traceability to the specimen and acceptance criteria."
        ],
        "record": "Report the barrier, test mode, traceable instrument, leakage or breakdown observation and acceptance result under the applicable method."
      },
      "notes": [
        "High-voltage test settings come from the applicable method and qualified lab."
      ],
      "url": "https://lemonergy.com/learn/glossary/dielectric-withstand-test/",
      "mentions": [
        "insulation-resistance"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:dielectric-withstand-test/topic:topic-testing",
      "source": "term:dielectric-withstand-test",
      "target": "topic:topic-testing",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:dielectric-withstand-test/term:dielectric-withstand-tester",
      "source": "term:dielectric-withstand-test",
      "target": "term:dielectric-withstand-tester",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:dielectric-withstand-test/term:battery-data-acquisition",
      "source": "term:dielectric-withstand-test",
      "target": "term:battery-data-acquisition",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:dielectric-withstand-test/term:testing",
      "source": "term:dielectric-withstand-test",
      "target": "term:testing",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:dielectric-withstand-test/term:dielectric-withstand-tester",
      "source": "term:dielectric-withstand-test",
      "target": "term:dielectric-withstand-tester",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:usesTestEquipment/term:dielectric-withstand-test/term:battery-data-acquisition",
      "source": "term:dielectric-withstand-test",
      "target": "term:battery-data-acquisition",
      "type": "usesTestEquipment",
      "properties": {
        "sourceFile": "wiki-editorial.json"
      }
    },
    {
      "id": "edge:mentions/dielectric-withstand-test/insulation-resistance",
      "source": "term:dielectric-withstand-test",
      "target": "term:insulation-resistance",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:dielectric-withstand-test/reference:sandia-abuse-manual",
      "source": "term:dielectric-withstand-test",
      "target": "reference:sandia-abuse-manual",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:dielectric-withstand-test/reference:sandia-batlab",
      "source": "term:dielectric-withstand-test",
      "target": "reference:sandia-batlab",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing",
      "type": "Topic",
      "label": "Testing methods",
      "properties": {
        "id": "topic-testing",
        "name": "Testing methods",
        "lede": "The measurements and test procedures that characterise a cell or pack, from capacity and pulse tests to abuse and environmental tests.",
        "context": "Record specimen, state, instrument, temperature and timing.",
        "example": "Resistance immediately after a current step can differ from a ten-second value because slower polarization contributes.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open capacity measurements"
      }
    },
    {
      "id": "term:dielectric-withstand-tester",
      "type": "Term",
      "label": "Dielectric-withstand tester",
      "properties": {
        "id": "dielectric-withstand-tester",
        "name": "Dielectric-withstand tester",
        "section": "topic-testing-equipment",
        "definition": "A dielectric-withstand tester applies a specified electrical stress to an insulation barrier and monitors leakage or breakdown. A high-voltage safety procedure defines the limits and precautions for the assembly.",
        "related": [
          "dielectric-withstand-test",
          "insulation-resistance-tester",
          "insulation-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "An accredited lab records the tested barrier, test mode and observed leakage against its own approved limits, alongside the instrument identifier and the specimen's test history."
        },
        "url": "https://lemonergy.com/learn/glossary/dielectric-withstand-tester/",
        "mentions": [
          "electrolyte-leakage"
        ]
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "term:testing",
      "type": "Term",
      "label": "Battery testing procedures",
      "properties": {
        "id": "testing",
        "name": "Battery testing procedures",
        "section": "topic-testing",
        "definition": "Battery testing procedures describe how to characterize performance, durability, environmental behavior and safety at cell, module or pack level. A test plan defines the specimen, conditions, equipment, measurements and the applicable evaluation method.",
        "related": [
          "capacity-test",
          "cycler",
          "reference-performance-test",
          "abuse-testing",
          "datasheet",
          "charging-strategies"
        ],
        "aka": [
          "Cell testing"
        ],
        "testChooser": [
          {
            "goal": "Measure performance",
            "term": "capacity-test",
            "title": "Capacity test",
            "description": "Measure how much charge and energy the battery delivers under defined conditions.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and cell fixture",
              "Procedure": "Condition the cell, then discharge at the specified current",
              "Record": "Ah, Wh, temperature, and cutoff voltage"
            },
            "action": "Open the capacity test"
          },
          {
            "goal": "Understand aging",
            "term": "cycle-life-test",
            "title": "Cycle-life test",
            "description": "Track how repeated cycling changes capacity and resistance.",
            "details": {
              "Equipment": "Cycler, temperature chamber, and data logger",
              "Procedure": "Cycle the battery and repeat reference performance tests",
              "Record": "Capacity, resistance, and charge throughput"
            },
            "action": "Open the cycle-life test"
          },
          {
            "goal": "Investigate a failure",
            "term": "post-mortem",
            "title": "Post-mortem analysis",
            "description": "Connect observations from a failed battery to the affected component and its test history.",
            "details": {
              "Equipment": "Specialist lab with appropriate containment",
              "Procedure": "Trace each sample to its location in the battery",
              "Record": "Test history, sample location, and preparation"
            },
            "action": "Open the post-mortem guide"
          },
          {
            "goal": "Plan qualification",
            "term": "transport-regulations",
            "title": "Start with the applicable standard",
            "description": "Match the test program to the product and its intended use. For transport, check which UN 38.3 tests apply.",
            "details": {
              "Define": "Specimen and intended use",
              "Confirm": "Applicable method and edition",
              "Record": "Test results and report reference"
            },
            "action": "Open the UN 38.3 guide"
          }
        ],
        "example": {
          "title": "Worked example",
          "text": "Choose an initial capacity test and pulse resistance baseline for the same specimen. Keep the state of charge, temperature and instrument channels comparable so later repeat measurements can reveal changes."
        },
        "guide": [
          {
            "title": "Performance and efficiency",
            "terms": [
              "capacity-test",
              "rate-test",
              "ocv-test",
              "pulse-test",
              "hppc",
              "dcir",
              "acir",
              "fast-charge-capability-test",
              "round-trip-efficiency-test",
              "drive-cycle-battery-test"
            ]
          },
          {
            "title": "Aging and thermal measurements",
            "terms": [
              "cycle-life-test",
              "calendar-life-test",
              "reference-performance-test",
              "self-discharge-test",
              "thermal-characterisation",
              "isothermal-calorimetry",
              "accelerating-rate-calorimetry"
            ]
          },
          {
            "title": "Electrochemical and material diagnostics",
            "terms": [
              "electrochemical-impedance-spectroscopy",
              "gitt",
              "pitt",
              "cyclic-voltammetry",
              "chronoamperometry",
              "chronopotentiometry",
              "ultra-high-precision-coulometry",
              "differential-voltage-analysis",
              "incremental-capacity-analysis",
              "laser-flash-analysis",
              "hot-disk-method",
              "ultrasonic-cell-testing",
              "x-ray-computed-tomography",
              "post-mortem"
            ]
          },
          {
            "title": "Manufacturing and battery management",
            "terms": [
              "end-of-line-testing",
              "electrode-peel-test",
              "tab-pull-test",
              "helium-leak-test",
              "swelling-test",
              "fault-injection-testing",
              "insulation-test",
              "dielectric-withstand-test"
            ]
          },
          {
            "title": "Environment and mechanics",
            "terms": [
              "altitude-simulation-test",
              "thermal-shock-test",
              "vibration-test",
              "mechanical-shock-test",
              "damp-heat-test",
              "salt-spray-test",
              "immersion-test",
              "halt-hass",
              "impact-test"
            ]
          },
          {
            "title": "Safety and abuse",
            "terms": [
              "abuse-testing",
              "oven-test",
              "crush-test",
              "nail-penetration",
              "overcharge-test",
              "short-circuit-test",
              "propagation-test",
              "vehicle-crash-test",
              "transport-impact-crush-test",
              "forced-discharge-test"
            ]
          },
          {
            "title": "Transport and qualification references",
            "terms": [
              "transport-regulations",
              "iec-62660",
              "iso-12405",
              "iec-62133",
              "iec-62619",
              "un-r100",
              "ul-9540a"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/testing/",
        "mentions": []
      }
    },
    {
      "id": "term:dielectric-withstand-tester",
      "type": "Term",
      "label": "Dielectric-withstand tester",
      "properties": {
        "id": "dielectric-withstand-tester",
        "name": "Dielectric-withstand tester",
        "section": "topic-testing-equipment",
        "definition": "A dielectric-withstand tester applies a specified electrical stress to an insulation barrier and monitors leakage or breakdown. A high-voltage safety procedure defines the limits and precautions for the assembly.",
        "related": [
          "dielectric-withstand-test",
          "insulation-resistance-tester",
          "insulation-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "An accredited lab records the tested barrier, test mode and observed leakage against its own approved limits, alongside the instrument identifier and the specimen's test history."
        },
        "url": "https://lemonergy.com/learn/glossary/dielectric-withstand-tester/",
        "mentions": [
          "electrolyte-leakage"
        ]
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "term:insulation-resistance",
      "type": "Term",
      "label": "Insulation resistance",
      "properties": {
        "id": "insulation-resistance",
        "name": "Insulation resistance",
        "aka": [
          "isolation resistance",
          "IMD"
        ],
        "section": "topic-hvsafety",
        "definition": "The resistance between the high-voltage circuit and the vehicle chassis, which must stay above about 100 Ω per volt of pack voltage so a person touching the chassis is safe. An insulation monitoring device measures it continuously.",
        "unit": "Ω/V",
        "related": [
          "pack-voltage",
          "high-voltage-interlock",
          "functional-safety",
          "insulation-test"
        ],
        "url": "https://lemonergy.com/learn/glossary/insulation-resistance/",
        "mentions": [
          "volt"
        ]
      }
    },
    {
      "id": "reference:sandia-abuse-manual",
      "type": "Reference",
      "label": "USABC Battery Abuse Testing Manual for Electric and Hybrid Vehicle Applications",
      "properties": {
        "title": "USABC Battery Abuse Testing Manual for Electric and Hybrid Vehicle Applications",
        "publisher": "Sandia National Laboratories",
        "url": "https://doi.org/10.2172/1838583",
        "type": "Test manual",
        "scope": "Electrical, thermal and mechanical abuse-test categories and reported observations.",
        "accessed": "2026-11-18"
      }
    },
    {
      "id": "reference:sandia-batlab",
      "type": "Reference",
      "label": "Battery Abuse Testing Laboratory",
      "properties": {
        "title": "Battery Abuse Testing Laboratory",
        "publisher": "Sandia National Laboratories",
        "url": "https://www.sandia.gov/research/facilities/battery-abuse-testing-laboratory-batlab/",
        "type": "Laboratory documentation",
        "scope": "Specialist safety testing facilities, mechanical abuse and thermal measurements.",
        "accessed": "2026-11-18"
      }
    }
  ]
}