      "definition": "The manufacturer’s specification sheet for a cell: nominal capacity, nominal voltage, voltage window, continuous and peak currents, operating temperatures, dimensions, mass and cycle life, each tied to the test conditions it was measured under.",
      "related": [
        "nominal-capacity",
        "nominal-voltage",
        "operating-temperature",
        "cycle-life",
        "iec-62620"
      ],
      "lesson": "fundamentals/battery-basics/#datasheet",
      "url": "https://lemonergy.com/learn/glossary/datasheet/",
      "mentions": [
        "voltage-window"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:985",
      "source": "term:datasheet",
      "target": "topic:topic-ratings",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:986",
      "source": "term:datasheet",
      "target": "term:nominal-capacity",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:987",
      "source": "term:datasheet",
      "target": "term:nominal-voltage",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:988",
      "source": "term:datasheet",
      "target": "term:operating-temperature",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:989",
      "source": "term:datasheet",
      "target": "term:cycle-life",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:990",
      "source": "term:datasheet",
      "target": "term:iec-62620",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/datasheet/voltage-window",
      "source": "term:datasheet",
      "target": "term:voltage-window",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:992",
      "source": "term:datasheet",
      "target": "lesson:fundamentals/battery-basics/",
      "type": "explainedIn",
      "properties": {
        "sourceFile": "terms.json",
        "url": "https://lemonergy.com/learn/fundamentals/battery-basics/#datasheet"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-ratings",
      "type": "Topic",
      "label": "Capacity, energy, power and ratings",
      "properties": {
        "id": "topic-ratings",
        "name": "Capacity, energy, power and ratings",
        "lede": "The numbers that size a cell and let two cells be compared.",
        "context": "Separate nameplate ratings from test results.",
        "example": "5 Ah at 3.6 V gives 18 Wh nominally. Integrated measured terminal power may give a different result.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/",
        "lesson_label": "Open capacity and C-rate"
      }
    },
    {
      "id": "term:nominal-capacity",
      "type": "Term",
      "label": "Nominal capacity",
      "properties": {
        "id": "nominal-capacity",
        "name": "Nominal capacity",
        "aka": [
          "rated capacity"
        ],
        "section": "topic-ratings",
        "definition": "The charge a cell is rated to deliver under specified test conditions — current, temperature, rest and voltage limits — usually in ampere-hours.",
        "unit": "Ah",
        "related": [
          "ampere-hour",
          "c-rate",
          "capacity-test",
          "usable-capacity",
          "state-of-health"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#nominal-capacity",
        "url": "https://lemonergy.com/learn/glossary/nominal-capacity/",
        "mentions": []
      }
    },
    {
      "id": "term:nominal-voltage",
      "type": "Term",
      "label": "Nominal voltage",
      "properties": {
        "id": "nominal-voltage",
        "name": "Nominal voltage",
        "section": "topic-ratings",
        "definition": "A representative average voltage of a cell over a full discharge, such as 3.6–3.7 V for an oxide/graphite cell or about 3.2 V for LFP/graphite. Multiplied by capacity, it gives nominal energy.",
        "unit": "V",
        "related": [
          "nominal-energy",
          "open-circuit-voltage",
          "voltage-window",
          "lfp"
        ],
        "lesson": "fundamentals/capacity-and-c-rate/#energy",
        "url": "https://lemonergy.com/learn/glossary/nominal-voltage/",
        "mentions": [
          "graphite"
        ]
      }
    },
    {
      "id": "term:operating-temperature",
      "type": "Term",
      "label": "Operating temperature",
      "properties": {
        "id": "operating-temperature",
        "name": "Operating temperature",
        "section": "topic-ratings",
        "definition": "The temperature range a cell may be charged and discharged in, typically 0–45 °C for charging and −20–60 °C for discharging. Charging below 0 °C risks lithium plating; above the range the cell ages fast and may vent.",
        "unit": "°C",
        "related": [
          "lithium-plating",
          "arrhenius",
          "thermal-management",
          "datasheet"
        ],
        "lesson": "fundamentals/battery-aging/#temperature",
        "url": "https://lemonergy.com/learn/glossary/operating-temperature/",
        "mentions": []
      }
    },
    {
      "id": "term:cycle-life",
      "type": "Term",
      "label": "Cycle life",
      "properties": {
        "id": "cycle-life",
        "name": "Cycle life",
        "section": "topic-ratings",
        "definition": "The number of full charge–discharge cycles a cell completes before its capacity falls to a stated fraction, usually 80 %, of its initial value under defined conditions. LFP cells reach several thousand cycles; high-energy NMC fewer.",
        "unit": "cycles",
        "related": [
          "end-of-life",
          "capacity-fade",
          "depth-of-discharge",
          "calendar-life",
          "equivalent-full-cycle",
          "cycle-life-test"
        ],
        "url": "https://lemonergy.com/learn/glossary/cycle-life/",
        "mentions": []
      }
    },
    {
      "id": "term:iec-62620",
      "type": "Term",
      "label": "IEC 62620",
      "properties": {
        "id": "iec-62620",
        "name": "IEC 62620",
        "section": "topic-standards-stationary",
        "definition": "The performance standard for industrial lithium cells and batteries: how to measure and declare capacity, endurance, internal resistance and self-discharge, so that datasheets from different makers can be compared.",
        "related": [
          "iec-62619",
          "datasheet",
          "capacity-test",
          "cycle-life"
        ],
        "url": "https://lemonergy.com/learn/glossary/iec-62620/",
        "mentions": [
          "internal-resistance",
          "self-discharge"
        ]
      }
    },
    {
      "id": "term:voltage-window",
      "type": "Term",
      "label": "Voltage window",
      "properties": {
        "id": "voltage-window",
        "name": "Voltage window",
        "aka": [
          "operating voltage range"
        ],
        "section": "topic-ratings",
        "definition": "The range between a cell’s lower and upper cutoff voltages, such as 2.5–4.2 V for an NMC/graphite cell. Staying inside it is what keeps the electrodes and electrolyte from degrading quickly.",
        "unit": "V",
        "related": [
          "cutoff-voltage",
          "overcharge",
          "over-discharge",
          "electrochemical-stability-window"
        ],
        "url": "https://lemonergy.com/learn/glossary/voltage-window/",
        "mentions": [
          "graphite",
          "electrolyte"
        ]
      }
    },
    {
      "id": "lesson:fundamentals/battery-basics/",
      "type": "Lesson",
      "label": "Lesson 0 · Battery basics",
      "properties": {
        "url": "https://lemonergy.com/learn/fundamentals/battery-basics/"
      }
    }
  ]
}