  "node": {
    "id": "term:battery-ultrasound-instrument",
    "type": "Term",
    "label": "Battery ultrasonic pulser and receiver",
    "properties": {
      "id": "battery-ultrasound-instrument",
      "name": "Battery ultrasonic pulser and receiver",
      "section": "topic-testing-equipment",
      "definition": "An ultrasonic pulser and receiver sends an acoustic excitation and measures its reflected or transmitted waveform. Transducer coupling, geometry and timing affect interpretation of the response.",
      "related": [
        "battery-test-equipment",
        "ultrasonic-cell-testing",
        "battery-data-acquisition"
      ],
      "example": {
        "title": "Worked example",
        "text": "Compare two synthetic waveforms with the same probe position and time reference. A signal that shifts when the contact is moved may reflect coupling changes rather than the specimen."
      },
      "url": "https://lemonergy.com/learn/glossary/battery-ultrasound-instrument/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:battery-ultrasound-instrument/topic:topic-testing-equipment",
      "source": "term:battery-ultrasound-instrument",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-ultrasound-instrument/term:battery-test-equipment",
      "source": "term:battery-ultrasound-instrument",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-ultrasound-instrument/term:ultrasonic-cell-testing",
      "source": "term:battery-ultrasound-instrument",
      "target": "term:ultrasonic-cell-testing",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-ultrasound-instrument/term:battery-data-acquisition",
      "source": "term:battery-ultrasound-instrument",
      "target": "term:battery-data-acquisition",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:battery-ultrasound-instrument/reference:xiang-characterization",
      "source": "term:battery-ultrasound-instrument",
      "target": "reference:xiang-characterization",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "term:ultrasonic-cell-testing",
      "type": "Term",
      "label": "Ultrasonic cell testing",
      "properties": {
        "id": "ultrasonic-cell-testing",
        "name": "Ultrasonic cell testing",
        "aka": [
          "acoustic testing",
          "acoustic time-of-flight",
          "ultrasound inspection"
        ],
        "section": "topic-testing",
        "definition": "Sending ultrasound pulses through a cell and tracking how their travel time and amplitude change. Electrode stiffness and density shift with lithiation, so the signal follows state of charge, while gas pockets and dry regions block sound — making it a way to map electrolyte wetting after filling and to detect gassing and lithium plating.",
        "related": [
          "wetting",
          "gas-generation",
          "state-of-charge",
          "lithium-plating",
          "end-of-line-testing",
          "battery-data-acquisition"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Retain waveforms, transit time or amplitude, source–receiver geometry and conditions. Acoustic changes alone do not uniquely identify a defect."
        },
        "procedure": {
          "equipment": [
            "battery-ultrasound-instrument",
            "battery-data-acquisition",
            "battery-cell-fixture"
          ],
          "steps": [
            "Choose a controlled transducer geometry and repeatable coupling method.",
            "Collect the reference and comparison signals at matched SOC and temperature.",
            "Interpret changes only after checking coupling and position repeatability."
          ],
          "record": "Retain waveforms, transit time or amplitude, source–receiver geometry and conditions. Acoustic changes alone do not uniquely identify a defect."
        },
        "url": "https://lemonergy.com/learn/glossary/ultrasonic-cell-testing/",
        "mentions": [
          "electrode",
          "electrolyte",
          "calcination"
        ]
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "reference:xiang-characterization",
      "type": "Reference",
      "label": "Advanced characterization techniques for solid state lithium battery research",
      "properties": {
        "title": "Advanced characterization techniques for solid state lithium battery research",
        "publisher": "Materials Today",
        "url": "https://doi.org/10.1016/j.mattod.2020.01.018",
        "type": "Review article",
        "scope": "X-ray, solid-state NMR and neutron methods in solid-state battery research.",
        "year": 2020,
        "authors": [
          "Yuxuan Xiang",
          "Xia Li",
          "Yongqiang Cheng",
          "Xueliang Sun",
          "Yong Yang"
        ],
        "accessed": "2026-10-27"
      }
    }
  ]
}