  "node": {
    "id": "term:battery-test-chamber",
    "type": "Term",
    "label": "Battery environmental chamber",
    "properties": {
      "id": "battery-test-chamber",
      "name": "Battery environmental chamber",
      "section": "topic-testing-equipment",
      "definition": "An environmental chamber controls air temperature and sometimes humidity around the specimen. The chamber setpoint and actual cell temperature can differ during soak and current cycling.",
      "related": [
        "thermal-shock-test",
        "damp-heat-test",
        "thermocouples-rtds",
        "cycler",
        "battery-test-equipment"
      ],
      "example": {
        "title": "Worked example",
        "text": "Log the setpoint alongside a chamber air probe and an attached surface sensor. Start a comparable performance measurement after the specimen has met the specified stabilization condition."
      },
      "url": "https://lemonergy.com/learn/glossary/battery-test-chamber/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:battery-test-chamber/topic:topic-testing-equipment",
      "source": "term:battery-test-chamber",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-test-chamber/term:thermal-shock-test",
      "source": "term:battery-test-chamber",
      "target": "term:thermal-shock-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-test-chamber/term:damp-heat-test",
      "source": "term:battery-test-chamber",
      "target": "term:damp-heat-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-test-chamber/term:thermocouples-rtds",
      "source": "term:battery-test-chamber",
      "target": "term:thermocouples-rtds",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-test-chamber/term:cycler",
      "source": "term:battery-test-chamber",
      "target": "term:cycler",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-test-chamber/term:battery-test-equipment",
      "source": "term:battery-test-chamber",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:battery-test-chamber/reference:inl-ev-tests",
      "source": "term:battery-test-chamber",
      "target": "reference:inl-ev-tests",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:thermal-shock-test",
      "type": "Term",
      "label": "Thermal shock and cycling test",
      "properties": {
        "id": "thermal-shock-test",
        "name": "Thermal shock and cycling test",
        "section": "topic-testing",
        "definition": "Moving a cell or pack rapidly between temperature extremes, typically −40 °C and +60 to +85 °C, for many cycles, to find seals, welds and housings that fail by differential expansion. It is in UN 38.3, R100 and most pack specifications.",
        "related": [
          "transport-regulations",
          "un-r100-part-2",
          "vibration-test",
          "abuse-testing",
          "mil-std-810",
          "battery-test-chamber"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Report the measured temperature history, transitions, specimen observations and method. UN 38.3 T.2 is a specific thermal test, not every thermal cycling method."
        },
        "procedure": {
          "equipment": [
            "battery-test-chamber",
            "thermocouples-rtds",
            "battery-data-acquisition"
          ],
          "steps": [
            "Confirm the governing environmental test and prepare the approved mounting and sensing.",
            "Track chamber transitions and specimen temperatures during prescribed exposure.",
            "Compare electrical and physical observations against the method."
          ],
          "record": "Report the measured temperature history, transitions, specimen observations and method. UN 38.3 T.2 is a specific thermal test, not every thermal cycling method."
        },
        "url": "https://lemonergy.com/learn/glossary/thermal-shock-test/",
        "mentions": [
          "un-r100"
        ]
      }
    },
    {
      "id": "term:damp-heat-test",
      "type": "Term",
      "label": "Damp heat test",
      "properties": {
        "id": "damp-heat-test",
        "name": "Damp heat test",
        "aka": [
          "humidity test",
          "cyclic damp heat",
          "IEC 60068-2-30"
        ],
        "section": "topic-testing",
        "definition": "Keeping a cell, module or pack warm and very humid, steadily or in cycles, to bring out corrosion, seal leaks and condensation that lower insulation resistance. The common cyclic version, IEC 60068-2-30, alternates between about 25 °C and 40 or 55 °C at over 90 % relative humidity in 24-hour cycles for several days.",
        "related": [
          "insulation-resistance",
          "enclosure",
          "ip-rating",
          "thermal-shock-test",
          "salt-spray-test",
          "battery-test-chamber"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Capture humidity and temperature history, recovery conditions, and evidence of corrosion, condensation or insulation change when relevant."
        },
        "procedure": {
          "equipment": [
            "battery-test-chamber",
            "insulation-resistance-tester",
            "battery-data-acquisition"
          ],
          "steps": [
            "Define whether the applicable procedure uses steady or cyclic humidity exposure.",
            "Log measured chamber temperature and humidity and record specimen state.",
            "Perform the defined post-exposure checks after the required recovery."
          ],
          "record": "Capture humidity and temperature history, recovery conditions, and evidence of corrosion, condensation or insulation change when relevant."
        },
        "url": "https://lemonergy.com/learn/glossary/damp-heat-test/",
        "mentions": [
          "relative-humidity"
        ]
      }
    },
    {
      "id": "term:thermocouples-rtds",
      "type": "Term",
      "label": "Thermocouples, RTDs and fibre-optic sensors",
      "properties": {
        "id": "thermocouples-rtds",
        "name": "Thermocouples, RTDs and fibre-optic sensors",
        "aka": [
          "thermocouple",
          "RTD",
          "Pt100",
          "resistance temperature detector",
          "fibre Bragg grating",
          "FBG"
        ],
        "section": "topic-thermal",
        "definition": "Temperature sensors used alongside the NTC thermistors of a BMS. Thermocouples, junctions of two dissimilar wires such as type K or T, are cheap, small and standard in cell testing, good to about ±1–2 °C; platinum RTDs such as the Pt100 reach a few tenths of a degree; fibre-optic sensors ignore electrical noise and can sit inside a cell.",
        "related": [
          "temperature-sensor",
          "thermography",
          "testing",
          "bms",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "Two sensors mounted on opposite sides of a pack module can read different temperatures during a transient. Use traceable calibration, suitable attachment and synchronized logging before comparing their values."
        },
        "url": "https://lemonergy.com/learn/glossary/thermocouples-rtds/",
        "mentions": []
      }
    },
    {
      "id": "term:cycler",
      "type": "Term",
      "label": "Battery cycler",
      "properties": {
        "id": "cycler",
        "name": "Battery cycler",
        "aka": [
          "battery tester",
          "cycling channel"
        ],
        "section": "topic-testing-equipment",
        "definition": "The instrument that charges and discharges cells to a programmed schedule while logging voltage, current and temperature, with one independent channel per cell. Laboratory cyclers resolve microvolts; production formation cyclers handle thousands of cells at once.",
        "related": [
          "testing",
          "capacity-test",
          "potentiostat",
          "formation",
          "cycler-file-formats",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "A cycler runs a programmed sequence across several channels. Compare commanded current, recorded current and individual stop reasons before aggregating capacity results across cells."
        },
        "url": "https://lemonergy.com/learn/glossary/cycler/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "reference:inl-ev-tests",
      "type": "Reference",
      "label": "Battery Test Manual For Electric Vehicles, Revision 3",
      "properties": {
        "title": "Battery Test Manual For Electric Vehicles, Revision 3",
        "publisher": "Idaho National Laboratory",
        "url": "https://www.osti.gov/servlets/purl/1186745",
        "type": "Test manual",
        "scope": "Performance characterization, pulse resistance/power, life testing and reference performance tests; historical 2015 edition.",
        "year": 2015,
        "authors": [
          "Jon P. Christopherson"
        ],
        "accessed": "2026-10-27"
      }
    }
  ]
}