  "node": {
    "id": "term:battery-gas-analysis",
    "type": "Term",
    "label": "Battery gas sampling and analysis",
    "properties": {
      "id": "battery-gas-analysis",
      "name": "Battery gas sampling and analysis",
      "section": "topic-testing-equipment",
      "definition": "Gas sampling equipment captures or analyzes gases released during battery testing. Sensor choice, sampling location, response time and calibration affect reported composition and concentration.",
      "related": [
        "off-gas",
        "gas-detection",
        "battery-abuse-enclosure",
        "battery-test-equipment"
      ],
      "example": {
        "title": "Worked example",
        "text": "Compare an optical event marker with the arrival of a gas signal. Report sampling delay and sensor response so the analyzer timestamp is not mistaken for the gas release time."
      },
      "url": "https://lemonergy.com/learn/glossary/battery-gas-analysis/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:battery-gas-analysis/topic:topic-testing-equipment",
      "source": "term:battery-gas-analysis",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-gas-analysis/term:off-gas",
      "source": "term:battery-gas-analysis",
      "target": "term:off-gas",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-gas-analysis/term:gas-detection",
      "source": "term:battery-gas-analysis",
      "target": "term:gas-detection",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-gas-analysis/term:battery-abuse-enclosure",
      "source": "term:battery-gas-analysis",
      "target": "term:battery-abuse-enclosure",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-gas-analysis/term:battery-test-equipment",
      "source": "term:battery-gas-analysis",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:battery-gas-analysis/reference:sandia-methods",
      "source": "term:battery-gas-analysis",
      "target": "reference:sandia-methods",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:battery-gas-analysis/reference:sandia-batlab",
      "source": "term:battery-gas-analysis",
      "target": "reference:sandia-batlab",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:off-gas",
      "type": "Term",
      "label": "Off-gas",
      "properties": {
        "id": "off-gas",
        "name": "Off-gas",
        "aka": [
          "vent gas"
        ],
        "section": "topic-safety",
        "definition": "The mixture released when a cell vents: electrolyte vapour, hydrogen, carbon monoxide, carbon dioxide and hydrocarbons, with hydrogen fluoride. It is flammable and toxic, and gas sensors detect it before smoke or heat in a storage container.",
        "related": [
          "venting",
          "hydrofluoric-acid",
          "gas-detection",
          "thermal-runaway"
        ],
        "url": "https://lemonergy.com/learn/glossary/off-gas/",
        "mentions": [
          "electrolyte"
        ]
      }
    },
    {
      "id": "term:gas-detection",
      "type": "Term",
      "label": "Gas detection",
      "properties": {
        "id": "gas-detection",
        "name": "Gas detection",
        "aka": [
          "off-gas detection"
        ],
        "section": "topic-safety",
        "definition": "Sensors in a pack or storage container that detect electrolyte vapour or hydrogen released before thermal runaway. Off-gas appears minutes before heat and smoke, which makes it the earliest practical warning.",
        "related": [
          "off-gas",
          "venting",
          "fire-suppression",
          "bms",
          "early-thermal-runaway-detection"
        ],
        "url": "https://lemonergy.com/learn/glossary/gas-detection/",
        "mentions": [
          "electrolyte",
          "thermal-runaway"
        ]
      }
    },
    {
      "id": "term:battery-abuse-enclosure",
      "type": "Term",
      "label": "Battery abuse test enclosure",
      "properties": {
        "id": "battery-abuse-enclosure",
        "name": "Battery abuse test enclosure",
        "section": "topic-testing-equipment",
        "definition": "A specialist abuse enclosure contains the test specimen and provides remote observation, ventilation and instrumentation appropriate to the expected event. The facility design and emergency plan are specific to the hazard.",
        "related": [
          "abuse-testing",
          "gas-detection",
          "propagation-test",
          "battery-data-acquisition",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "A laboratory aligns video, temperature, pack voltage and gas-channel timestamps so the test report can identify the order of observed events without inferring it from one sensor."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-abuse-enclosure/",
        "mentions": [
          "enclosure"
        ]
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "reference:sandia-methods",
      "type": "Reference",
      "label": "Safety and reliability",
      "properties": {
        "title": "Safety and reliability",
        "publisher": "Sandia National Laboratories",
        "url": "https://energy.sandia.gov/programs/energy-storage/safety-and-reliability/",
        "type": "Laboratory documentation",
        "scope": "Battery calorimetry, CT imaging, immersion and synchronized recording at a specialist laboratory.",
        "accessed": "2026-11-18"
      }
    },
    {
      "id": "reference:sandia-batlab",
      "type": "Reference",
      "label": "Battery Abuse Testing Laboratory",
      "properties": {
        "title": "Battery Abuse Testing Laboratory",
        "publisher": "Sandia National Laboratories",
        "url": "https://www.sandia.gov/research/facilities/battery-abuse-testing-laboratory-batlab/",
        "type": "Laboratory documentation",
        "scope": "Specialist safety testing facilities, mechanical abuse and thermal measurements.",
        "accessed": "2026-11-18"
      }
    }
  ]
}