  "node": {
    "id": "term:battery-data-acquisition",
    "type": "Term",
    "label": "Battery data acquisition system",
    "properties": {
      "id": "battery-data-acquisition",
      "name": "Battery data acquisition system",
      "section": "topic-testing-equipment",
      "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
      "related": [
        "thermocouples-rtds",
        "voltage-sense",
        "kelvin-sensing",
        "pulse-test",
        "battery-test-equipment"
      ],
      "example": {
        "title": "Worked example",
        "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
      },
      "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
      "mentions": []
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:battery-data-acquisition/topic:topic-testing-equipment",
      "source": "term:battery-data-acquisition",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-data-acquisition/term:thermocouples-rtds",
      "source": "term:battery-data-acquisition",
      "target": "term:thermocouples-rtds",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-data-acquisition/term:voltage-sense",
      "source": "term:battery-data-acquisition",
      "target": "term:voltage-sense",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-data-acquisition/term:kelvin-sensing",
      "source": "term:battery-data-acquisition",
      "target": "term:kelvin-sensing",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-data-acquisition/term:pulse-test",
      "source": "term:battery-data-acquisition",
      "target": "term:pulse-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-data-acquisition/term:battery-test-equipment",
      "source": "term:battery-data-acquisition",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:battery-data-acquisition/reference:inl-ev-tests",
      "source": "term:battery-data-acquisition",
      "target": "reference:inl-ev-tests",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:battery-data-acquisition/reference:sandia-batlab",
      "source": "term:battery-data-acquisition",
      "target": "reference:sandia-batlab",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:thermocouples-rtds",
      "type": "Term",
      "label": "Thermocouples, RTDs and fibre-optic sensors",
      "properties": {
        "id": "thermocouples-rtds",
        "name": "Thermocouples, RTDs and fibre-optic sensors",
        "aka": [
          "thermocouple",
          "RTD",
          "Pt100",
          "resistance temperature detector",
          "fibre Bragg grating",
          "FBG"
        ],
        "section": "topic-thermal",
        "definition": "Temperature sensors used alongside the NTC thermistors of a BMS. Thermocouples, junctions of two dissimilar wires such as type K or T, are cheap, small and standard in cell testing, good to about ±1–2 °C; platinum RTDs such as the Pt100 reach a few tenths of a degree; fibre-optic sensors ignore electrical noise and can sit inside a cell.",
        "related": [
          "temperature-sensor",
          "thermography",
          "testing",
          "bms",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "Two sensors mounted on opposite sides of a pack module can read different temperatures during a transient. Use traceable calibration, suitable attachment and synchronized logging before comparing their values."
        },
        "url": "https://lemonergy.com/learn/glossary/thermocouples-rtds/",
        "mentions": []
      }
    },
    {
      "id": "term:voltage-sense",
      "type": "Term",
      "label": "Voltage sensing",
      "properties": {
        "id": "voltage-sense",
        "name": "Voltage sensing",
        "aka": [
          "cell tap",
          "sense line"
        ],
        "section": "topic-pack",
        "definition": "Measuring each series cell group’s voltage through a wire or flexible circuit from its busbar to the monitoring chip. Millivolt accuracy matters because the BMS reads SOC and detects faults from these numbers.",
        "unit": "mV",
        "related": [
          "cell-supervision-circuit",
          "bms",
          "busbar",
          "open-circuit-voltage",
          "afe",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "Pack voltage and individual cell channels tell different stories near the top of charge. Log both with timestamps so a weakest-cell limit can be matched to the recorded pack current."
        },
        "url": "https://lemonergy.com/learn/glossary/voltage-sense/",
        "mentions": [
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:kelvin-sensing",
      "type": "Term",
      "label": "Kelvin sensing",
      "properties": {
        "id": "kelvin-sensing",
        "name": "Kelvin sensing",
        "aka": [
          "four-wire sensing",
          "four-terminal sensing",
          "4-wire measurement",
          "separate sense and balancing leads"
        ],
        "section": "topic-data",
        "definition": "Measuring voltage through a separate pair of leads that carry no current, so the drop along current-carrying wires and joints is left out. In a BMS, 100 mA of balancing current through 0.5 Ω of sense wire would add a 50 mV error, so designs either give balancing its own leads or pause balancing while measuring.",
        "related": [
          "voltage-sense",
          "cell-balancing",
          "current-sensor",
          "contact-resistance",
          "dcir",
          "thermoelectric-error"
        ],
        "example": {
          "title": "Worked example",
          "text": "Separate current and voltage sense paths make the voltage instrument read nearer the intended battery contacts. Document where the clips touch so a later test includes the same resistance contributions."
        },
        "url": "https://lemonergy.com/learn/glossary/kelvin-sensing/",
        "mentions": [
          "bms"
        ]
      }
    },
    {
      "id": "term:pulse-test",
      "type": "Term",
      "label": "Pulse test",
      "properties": {
        "id": "pulse-test",
        "name": "Pulse test",
        "aka": [
          "current pulse test",
          "DC pulse"
        ],
        "section": "topic-testing",
        "definition": "Applying a current step of defined size and duration and recording the voltage response. The instant voltage step gives the ohmic resistance, the following curve the slower polarization; HPPC is a standardised sequence of such pulses across state of charge.",
        "related": [
          "hppc",
          "dcir",
          "internal-resistance",
          "relaxation",
          "equivalent-circuit-model",
          "cycler"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Report current, voltage, sample rate, pulse width, sampling window, temperature and direction. A pulse resistance without a measurement time is ambiguous."
        },
        "procedure": {
          "equipment": [
            "cycler",
            "bidirectional-dc-supply",
            "battery-data-acquisition"
          ],
          "steps": [
            "Stabilize SOC and temperature and record a pre-pulse baseline.",
            "Apply the approved current waveform and time-align current and voltage including the initial edge.",
            "Monitor relaxation and evaluate the voltage change at the declared elapsed time."
          ],
          "record": "Report current, voltage, sample rate, pulse width, sampling window, temperature and direction. A pulse resistance without a measurement time is ambiguous."
        },
        "url": "https://lemonergy.com/learn/glossary/pulse-test/",
        "mentions": [
          "polarization",
          "state-of-charge"
        ]
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "reference:inl-ev-tests",
      "type": "Reference",
      "label": "Battery Test Manual For Electric Vehicles, Revision 3",
      "properties": {
        "title": "Battery Test Manual For Electric Vehicles, Revision 3",
        "publisher": "Idaho National Laboratory",
        "url": "https://www.osti.gov/servlets/purl/1186745",
        "type": "Test manual",
        "scope": "Performance characterization, pulse resistance/power, life testing and reference performance tests; historical 2015 edition.",
        "year": 2015,
        "authors": [
          "Jon P. Christopherson"
        ],
        "accessed": "2026-10-27"
      }
    },
    {
      "id": "reference:sandia-batlab",
      "type": "Reference",
      "label": "Battery Abuse Testing Laboratory",
      "properties": {
        "title": "Battery Abuse Testing Laboratory",
        "publisher": "Sandia National Laboratories",
        "url": "https://www.sandia.gov/research/facilities/battery-abuse-testing-laboratory-batlab/",
        "type": "Laboratory documentation",
        "scope": "Specialist safety testing facilities, mechanical abuse and thermal measurements.",
        "accessed": "2026-11-18"
      }
    }
  ]
}