  "node": {
    "id": "term:battery-calorimeter",
    "type": "Term",
    "label": "Battery calorimeter",
    "properties": {
      "id": "battery-calorimeter",
      "name": "Battery calorimeter",
      "section": "topic-testing-equipment",
      "definition": "A calorimeter measures heat release or self-heating under a defined configuration. Isothermal calorimeters measure heat flow near a fixed temperature, while accelerating-rate instruments track self-heating under near-adiabatic conditions.",
      "related": [
        "isothermal-calorimetry",
        "accelerating-rate-calorimetry",
        "differential-scanning-calorimetry",
        "battery-test-equipment"
      ],
      "example": {
        "title": "Worked example",
        "text": "At the same electrical cycling condition, compare heat-flow traces only after accounting for the instrument response, background and the placement of the specimen and its sensors."
      },
      "url": "https://lemonergy.com/learn/glossary/battery-calorimeter/",
      "mentions": [
        "adiabatic-isothermal"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:battery-calorimeter/topic:topic-testing-equipment",
      "source": "term:battery-calorimeter",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-calorimeter/term:isothermal-calorimetry",
      "source": "term:battery-calorimeter",
      "target": "term:isothermal-calorimetry",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-calorimeter/term:accelerating-rate-calorimetry",
      "source": "term:battery-calorimeter",
      "target": "term:accelerating-rate-calorimetry",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-calorimeter/term:differential-scanning-calorimetry",
      "source": "term:battery-calorimeter",
      "target": "term:differential-scanning-calorimetry",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-calorimeter/term:battery-test-equipment",
      "source": "term:battery-calorimeter",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/battery-calorimeter/adiabatic-isothermal",
      "source": "term:battery-calorimeter",
      "target": "term:adiabatic-isothermal",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:battery-calorimeter/reference:sandia-methods",
      "source": "term:battery-calorimeter",
      "target": "reference:sandia-methods",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:isothermal-calorimetry",
      "type": "Term",
      "label": "Isothermal calorimetry",
      "properties": {
        "id": "isothermal-calorimetry",
        "name": "Isothermal calorimetry",
        "aka": [
          "isothermal microcalorimetry",
          "IMC",
          "heat-flow calorimetry"
        ],
        "section": "topic-testing",
        "definition": "Holding a cell at constant temperature inside a calorimeter and measuring the heat it gives off, down to microwatts, while it cycles or rests. It separates reversible entropic heat from irreversible losses and reveals the parasitic heat of slow side reactions, a quick indicator of how long a cell will last.",
        "related": [
          "heat-generation",
          "entropy-coefficient",
          "thermal-characterisation",
          "accelerating-rate-calorimetry",
          "ultra-high-precision-coulometry",
          "battery-calorimeter"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Report heat flow, integration interval, specimen temperature, electrical conditions and baseline correction."
        },
        "procedure": {
          "equipment": [
            "battery-calorimeter",
            "cycler",
            "battery-data-acquisition"
          ],
          "steps": [
            "Establish the instrument baseline and a stable thermal boundary.",
            "Record heat flow and electrical measurements through the declared test sequence.",
            "Correct for the defined background and account for the instrument response."
          ],
          "record": "Report heat flow, integration interval, specimen temperature, electrical conditions and baseline correction."
        },
        "url": "https://lemonergy.com/learn/glossary/isothermal-calorimetry/",
        "mentions": []
      }
    },
    {
      "id": "term:accelerating-rate-calorimetry",
      "type": "Term",
      "label": "Accelerating rate calorimetry",
      "properties": {
        "id": "accelerating-rate-calorimetry",
        "name": "Accelerating rate calorimetry",
        "abbr": "ARC",
        "section": "topic-safety",
        "definition": "A test in which a cell sits in an adiabatic chamber that follows its temperature, so any self-heating is not lost to the surroundings. It measures the onset temperature, the self-heating rate and the temperature at which runaway becomes unstoppable.",
        "related": [
          "onset-temperature",
          "thermal-runaway",
          "differential-scanning-calorimetry",
          "battery-calorimeter",
          "battery-abuse-enclosure",
          "thermocouples-rtds"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Record self-heating rate versus temperature, instrument configuration, event timeline and any thermal inertia correction."
        },
        "procedure": {
          "equipment": [
            "battery-calorimeter",
            "battery-abuse-enclosure",
            "thermocouples-rtds"
          ],
          "steps": [
            "A qualified lab selects the calorimetry method, fixture and protected test facility.",
            "The lab synchronizes self-heating observations with specimen temperature and other event channels.",
            "Review the resulting thermal history and the assumptions behind any correction."
          ],
          "record": "Record self-heating rate versus temperature, instrument configuration, event timeline and any thermal inertia correction."
        },
        "url": "https://lemonergy.com/learn/glossary/accelerating-rate-calorimetry/",
        "mentions": [
          "adiabatic-isothermal"
        ]
      }
    },
    {
      "id": "term:differential-scanning-calorimetry",
      "type": "Term",
      "label": "Differential scanning calorimetry",
      "properties": {
        "id": "differential-scanning-calorimetry",
        "name": "Differential scanning calorimetry",
        "abbr": "DSC",
        "section": "topic-analysis",
        "definition": "Heating a milligram sample at a steady rate and recording the heat it releases or absorbs. It gives the decomposition temperatures and heats of electrode materials and electrolyte, inputs to any thermal-runaway assessment.",
        "related": [
          "accelerating-rate-calorimetry",
          "onset-temperature",
          "thermal-runaway",
          "thermogravimetric-analysis"
        ],
        "url": "https://lemonergy.com/learn/glossary/differential-scanning-calorimetry/",
        "mentions": [
          "electrode",
          "electrolyte"
        ]
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "term:adiabatic-isothermal",
      "type": "Term",
      "label": "Adiabatic and isothermal conditions",
      "properties": {
        "id": "adiabatic-isothermal",
        "name": "Adiabatic and isothermal conditions",
        "aka": [
          "adiabatic",
          "isothermal"
        ],
        "section": "topic-thermal",
        "definition": "Two idealised thermal boundaries used in testing. Adiabatic means no heat escapes, so every joule raises the sample’s temperature — the principle of accelerating rate calorimetry and the worst case for a pack whose cooling fails. Isothermal means the sample is held at constant temperature while the heat it releases is measured, as in isothermal calorimetry.",
        "related": [
          "accelerating-rate-calorimetry",
          "heat-generation",
          "thermal-characterisation",
          "thermal-runaway"
        ],
        "url": "https://lemonergy.com/learn/glossary/adiabatic-isothermal/",
        "mentions": [
          "joule",
          "isothermal-calorimetry"
        ]
      }
    },
    {
      "id": "reference:sandia-methods",
      "type": "Reference",
      "label": "Safety and reliability",
      "properties": {
        "title": "Safety and reliability",
        "publisher": "Sandia National Laboratories",
        "url": "https://energy.sandia.gov/programs/energy-storage/safety-and-reliability/",
        "type": "Laboratory documentation",
        "scope": "Battery calorimetry, CT imaging, immersion and synchronized recording at a specialist laboratory.",
        "accessed": "2026-11-18"
      }
    }
  ]
}