  "node": {
    "id": "term:battery-abuse-enclosure",
    "type": "Term",
    "label": "Battery abuse test enclosure",
    "properties": {
      "id": "battery-abuse-enclosure",
      "name": "Battery abuse test enclosure",
      "section": "topic-testing-equipment",
      "definition": "A specialist abuse enclosure contains the test specimen and provides remote observation, ventilation and instrumentation appropriate to the expected event. The facility design and emergency plan are specific to the hazard.",
      "related": [
        "abuse-testing",
        "gas-detection",
        "propagation-test",
        "battery-data-acquisition",
        "battery-test-equipment"
      ],
      "example": {
        "title": "Worked example",
        "text": "A laboratory aligns video, temperature, pack voltage and gas-channel timestamps so the test report can identify the order of observed events without inferring it from one sensor."
      },
      "url": "https://lemonergy.com/learn/glossary/battery-abuse-enclosure/",
      "mentions": [
        "enclosure"
      ]
    }
  },
  "edges": [
    {
      "id": "edge:belongsTo/term:battery-abuse-enclosure/topic:topic-testing-equipment",
      "source": "term:battery-abuse-enclosure",
      "target": "topic:topic-testing-equipment",
      "type": "belongsTo",
      "properties": {
        "sourceFile": "terms.json"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-abuse-enclosure/term:abuse-testing",
      "source": "term:battery-abuse-enclosure",
      "target": "term:abuse-testing",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-abuse-enclosure/term:gas-detection",
      "source": "term:battery-abuse-enclosure",
      "target": "term:gas-detection",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-abuse-enclosure/term:propagation-test",
      "source": "term:battery-abuse-enclosure",
      "target": "term:propagation-test",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-abuse-enclosure/term:battery-data-acquisition",
      "source": "term:battery-abuse-enclosure",
      "target": "term:battery-data-acquisition",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:relatedTo/term:battery-abuse-enclosure/term:battery-test-equipment",
      "source": "term:battery-abuse-enclosure",
      "target": "term:battery-test-equipment",
      "type": "relatedTo",
      "properties": {
        "sourceFile": "terms.json",
        "meaning": "Related context; not a causal claim"
      }
    },
    {
      "id": "edge:mentions/battery-abuse-enclosure/enclosure",
      "source": "term:battery-abuse-enclosure",
      "target": "term:enclosure",
      "type": "mentions",
      "properties": {
        "sourceFile": "terms.json",
        "method": "build_glossary.mention_index + mentions",
        "field": "definition",
        "meaning": "Text mention; not a causal claim"
      }
    },
    {
      "id": "edge:cites/term:battery-abuse-enclosure/reference:sandia-batlab",
      "source": "term:battery-abuse-enclosure",
      "target": "reference:sandia-batlab",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    },
    {
      "id": "edge:cites/term:battery-abuse-enclosure/reference:sandia-methods",
      "source": "term:battery-abuse-enclosure",
      "target": "reference:sandia-methods",
      "type": "cites",
      "properties": {
        "sourceFile": "wiki-references.json",
        "scope": "direct technical reference"
      }
    }
  ],
  "neighbors": [
    {
      "id": "topic:topic-testing-equipment",
      "type": "Topic",
      "label": "Testing equipment and instrumentation",
      "properties": {
        "id": "topic-testing-equipment",
        "name": "Testing equipment and instrumentation",
        "lede": "Sources, loads, fixtures and instruments for electrical, thermal, environmental and mechanical measurements.",
        "context": "Lemonergy models selected electrical and thermal measurements with simulated sensors and protocol steps. Test instrument selection, calibration and safety qualification belong to the laboratory.",
        "example": "On a pulse bench, compare commanded current with measured current and the voltage at the specimen sense points. Report the timing, ranges and calibration before deriving resistance.",
        "lesson_url": "https://lemonergy.com/learn/fundamentals/capacity-and-c-rate/#real-cells",
        "lesson_label": "Open the cell measurement examples"
      }
    },
    {
      "id": "term:abuse-testing",
      "type": "Term",
      "label": "Abuse testing",
      "properties": {
        "id": "abuse-testing",
        "name": "Abuse testing",
        "section": "topic-safety",
        "definition": "Deliberately driving cells and packs beyond their limits — overcharge, crush, nail penetration, external short, heating, drop — to see how they fail. Standards define each test and rank the outcome on a hazard scale from no effect to explosion.",
        "related": [
          "nail-penetration",
          "overcharge-test",
          "crush-test",
          "short-circuit-test",
          "hazard-level",
          "oven-test"
        ],
        "example": {
          "title": "What the report shows",
          "text": "Use common conditions for comparison and retain measurements in addition to the conclusion. Capture specimen and standard identity, observed events, synchronized measurement records, deviations, and the evaluation scope."
        },
        "procedure": {
          "equipment": [
            "battery-abuse-enclosure",
            "battery-data-acquisition",
            "battery-gas-analysis"
          ],
          "steps": [
            "Choose the applicable electrical, thermal or mechanical test category with the specialist laboratory.",
            "Define specimen state, facility controls and synchronized measurement channels under the governing method.",
            "Report event progression and observations against that method's criteria."
          ],
          "record": "Capture specimen and standard identity, observed events, synchronized measurement records, deviations, and the evaluation scope."
        },
        "url": "https://lemonergy.com/learn/glossary/abuse-testing/",
        "mentions": [
          "overcharge"
        ]
      }
    },
    {
      "id": "term:gas-detection",
      "type": "Term",
      "label": "Gas detection",
      "properties": {
        "id": "gas-detection",
        "name": "Gas detection",
        "aka": [
          "off-gas detection"
        ],
        "section": "topic-safety",
        "definition": "Sensors in a pack or storage container that detect electrolyte vapour or hydrogen released before thermal runaway. Off-gas appears minutes before heat and smoke, which makes it the earliest practical warning.",
        "related": [
          "off-gas",
          "venting",
          "fire-suppression",
          "bms",
          "early-thermal-runaway-detection"
        ],
        "url": "https://lemonergy.com/learn/glossary/gas-detection/",
        "mentions": [
          "electrolyte",
          "thermal-runaway"
        ]
      }
    },
    {
      "id": "term:propagation-test",
      "type": "Term",
      "label": "Thermal propagation test",
      "properties": {
        "id": "propagation-test",
        "name": "Thermal propagation test",
        "section": "topic-safety",
        "definition": "Triggering thermal runaway in one cell of a module or pack — by heater, nail or overcharge — and measuring whether and how fast it spreads. Regulations now require at least a warning period, five minutes in several markets, before the cabin is at risk.",
        "related": [
          "thermal-propagation",
          "abuse-testing",
          "thermal-barrier",
          "gtr-20",
          "battery-abuse-enclosure",
          "battery-gas-analysis"
        ],
        "example": {
          "title": "What the report shows",
          "text": "The test record connects the specimen and conditions to the observation. Record module temperature, event chronology and spread to neighboring units. The report distinguishes the level tested, the initiating event and subsequent spread."
        },
        "procedure": {
          "equipment": [
            "battery-abuse-enclosure",
            "battery-gas-analysis",
            "battery-data-acquisition"
          ],
          "steps": [
            "Identify the specimen and controlled test method with the qualified laboratory.",
            "The lab conducts the exposure and records synchronized observations through the required monitoring period.",
            "Review the measured events and document the assessment using the governing method."
          ],
          "record": "Record module temperature, event chronology and spread to neighboring units. The report distinguishes the level tested, the initiating event and subsequent spread."
        },
        "notes": [
          "These tests require a qualified laboratory, a controlled facility and the applicable test method. The sequence describes the lab's work and report at a high level."
        ],
        "url": "https://lemonergy.com/learn/glossary/propagation-test/",
        "mentions": [
          "overcharge",
          "thermal-runaway"
        ]
      }
    },
    {
      "id": "term:battery-data-acquisition",
      "type": "Term",
      "label": "Battery data acquisition system",
      "properties": {
        "id": "battery-data-acquisition",
        "name": "Battery data acquisition system",
        "section": "topic-testing-equipment",
        "definition": "A data acquisition system records and synchronizes channels such as voltage, temperature, current, pressure and displacement. Isolation, bandwidth and time alignment matter when different instruments observe the same event.",
        "related": [
          "thermocouples-rtds",
          "voltage-sense",
          "kelvin-sensing",
          "pulse-test",
          "battery-test-equipment"
        ],
        "example": {
          "title": "Worked example",
          "text": "During a fictional pulse, the voltage jumps before a slow temperature sensor changes. Record trigger time and each channel's sample rate to distinguish timing offsets from real thermal delay."
        },
        "url": "https://lemonergy.com/learn/glossary/battery-data-acquisition/",
        "mentions": []
      }
    },
    {
      "id": "term:battery-test-equipment",
      "type": "Term",
      "label": "Battery testing equipment",
      "properties": {
        "id": "battery-test-equipment",
        "name": "Battery testing equipment",
        "section": "topic-testing-equipment",
        "definition": "Battery testing equipment controls the electrical and environmental conditions applied to a cell, module or pack and records its response. The test objective determines the instrument, fixture, sensing range and safety provisions.",
        "related": [
          "testing",
          "cycler",
          "potentiostat",
          "charging-strategies"
        ],
        "example": {
          "title": "Worked example",
          "text": "A capacity bench and an environmental screening station may both record voltage and temperature. Only the capacity bench needs a calibrated source and load that can integrate current over the full cycle."
        },
        "guide": [
          {
            "title": "Source, sink and electrical measurement",
            "terms": [
              "cycler",
              "bidirectional-dc-supply",
              "electronic-load",
              "battery-current-transducer",
              "battery-cell-fixture",
              "kelvin-sensing",
              "voltage-sense"
            ]
          },
          {
            "title": "Electrochemical instrumentation",
            "terms": [
              "potentiostat",
              "battery-impedance-analyzer",
              "working-and-counter-electrode",
              "reference-electrode"
            ]
          },
          {
            "title": "Environment, thermal and mechanical equipment",
            "terms": [
              "battery-test-chamber",
              "thermocouples-rtds",
              "battery-coolant-conditioner",
              "battery-altitude-chamber",
              "battery-calorimeter",
              "battery-shaker",
              "battery-material-test-frame",
              "battery-thickness-gauge",
              "laser-flash-analyzer",
              "transient-plane-source-analyzer"
            ]
          },
          {
            "title": "Safety, controls and inspection",
            "terms": [
              "battery-data-acquisition",
              "insulation-resistance-tester",
              "dielectric-withstand-tester",
              "battery-abuse-enclosure",
              "battery-gas-analysis",
              "battery-pack-hil-bench",
              "x-ray-computed-tomography",
              "scanning-electron-microscopy",
              "gas-chromatography-mass-spectrometry",
              "helium-leak-detector",
              "battery-ultrasound-instrument"
            ]
          }
        ],
        "url": "https://lemonergy.com/learn/glossary/battery-test-equipment/",
        "mentions": []
      }
    },
    {
      "id": "term:enclosure",
      "type": "Term",
      "label": "Enclosure",
      "properties": {
        "id": "enclosure",
        "name": "Enclosure",
        "aka": [
          "battery housing",
          "battery tray"
        ],
        "section": "topic-pack",
        "definition": "The sealed case that carries the modules, protects them in a crash, keeps water out to an IP67 rating or better and vents gas in a thermal event. In many cars it is a structural part of the body.",
        "related": [
          "pack",
          "ip-rating",
          "cell-to-chassis",
          "venting",
          "gigacasting",
          "ul-94"
        ],
        "url": "https://lemonergy.com/learn/glossary/enclosure/",
        "mentions": []
      }
    },
    {
      "id": "reference:sandia-batlab",
      "type": "Reference",
      "label": "Battery Abuse Testing Laboratory",
      "properties": {
        "title": "Battery Abuse Testing Laboratory",
        "publisher": "Sandia National Laboratories",
        "url": "https://www.sandia.gov/research/facilities/battery-abuse-testing-laboratory-batlab/",
        "type": "Laboratory documentation",
        "scope": "Specialist safety testing facilities, mechanical abuse and thermal measurements.",
        "accessed": "2026-11-18"
      }
    },
    {
      "id": "reference:sandia-methods",
      "type": "Reference",
      "label": "Safety and reliability",
      "properties": {
        "title": "Safety and reliability",
        "publisher": "Sandia National Laboratories",
        "url": "https://energy.sandia.gov/programs/energy-storage/safety-and-reliability/",
        "type": "Laboratory documentation",
        "scope": "Battery calorimetry, CT imaging, immersion and synchronized recording at a specialist laboratory.",
        "accessed": "2026-11-18"
      }
    }
  ]
}