Panasonic NCR18650PF
2.7 Ah cylindrical cell.
Every value read from the datasheet, with the conditions it was stated at.
Compare in the finderSource documentRecord as JSON (API)Report a correction
- Capacity1
- 2.7Ah
- Nominal voltage
- 3.6V
- Energy2
- 9.72Wh
- Mass
- 47g
- Specific energy
- 207Wh/kg
- Energy density
- 577Wh/L
- Dimensions
- Ø 18.5 × 65.3mm
- Operating temperature3
- −20 to 60°C
- 1Capacity: 20 °C.
- 2Energy: calculated by Lemonergy from stated values: capacity × voltage.
- 3Operating temperature: discharge; charge 10 to 45 °C.
- Not stated by the source: continuous discharge, cycle life, internal resistance.
Curves
49 curves from 4 documents. A further source for this battery, the maker's datasheet: Panasonic NCR18650PF Specification (5 slides, footer code 3E3Z6JTAS): the three figures, plots 35 curves; they are drawn below with its name on each figure. A further source for this battery, a journal article independent of the maker: Han, S. (2024), Optimal Charging Current Protocol with Multi-Stage Constant Current Using Dandelion Optimizer for Time-Domain Modeled Lithium-Ion Batteries, Applied Sciences 14(23): 11320 (CC BY 4.0), plots 3 curves; they are drawn below with its name on each figure. A further source for this battery, a dataset independent of the maker: Jiang, J. (2026), VTAC-LiB: A Variable-Temperature Aging and Characterization Dataset for Lithium-Ion Batteries, Zenodo (CC BY 4.0), plots 6 curves; they are drawn below with its name on each figure. A further source for this battery, a journal article independent of the maker: Zhang, L., Mu, Z., Gao, X. (2018), Coupling Analysis and Performance Study of Commercial 18650 Lithium-Ion Batteries under Conditions of Temperature and Vibration, Energies 11(10): 2856 (CC BY 4.0), plots 5 curves; they are drawn below with its name on each figure.
Discharge
Select a line to hide or show it; double-click to see it alone.
review/revisions/panasonic/ncr18650pf-specification-3e3z6jtas-figures.yaml.Table: 15 lines
| Line | Points | Capacity at cut-off, mAh | Notes |
|---|---|---|---|
| 2 A | 293 | 2772.0 | |
| 2 A | 275 | 2773.4 | |
| 2 A | 290 | 2770.5 | |
| 4 A | 284 | 2763.4 | |
| 4 A | 285 | 2764.9 | |
| 4 A | 280 | 2760.6 | |
| 6 A | 746 | 2786.2 | |
| 6 A | 747 | 2787.6 | |
| 6 A | 745 | 2783.3 | |
| 8 A | 899 | 2806.0 | |
| 8 A | 899 | 2806.0 | |
| 8 A | 901 | 2806.0 | |
| 10 A | 742 | 2810.3 | |
| 10 A | 760 | 2810.3 | |
| 10 A | 756 | 2810.3 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/panasonic/ncr18650pf-specification-3e3z6jtas-figures.yaml.Table: 2 lines
| Line | Points | Capacity at cut-off, mAh | Notes |
|---|---|---|---|
| 25 °C | 270 | 2783.4 | |
| 0 °C | 225 | 2558.0 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/panasonic/ncr18650pf-zhang-2018-energies.yaml.Table: 5 lines
| Line | Points | Capacity at cut-off, Ah | Notes |
|---|---|---|---|
| 45 °C | 1714 | 2.849 | |
| 30 °C | 1686 | 2.785 | |
| 15 °C | 1642 | 2.635 | |
| 0 °C | 1496 | 2.536 | |
| −15 °C | 1504 | 2.447 |
Charge
review/digitisation/paper-10-3390-app142311320-fig6a.json). Curves from this document are in review/revisions/panasonic/ncr18650pf-han-2024-applsci.yaml.Table: 1 line
| Line | Points | Notes |
|---|---|---|
| Experiment | 274 |
review/digitisation/paper-10-3390-app142311320-fig6b.json). Curves from this document are in review/revisions/panasonic/ncr18650pf-han-2024-applsci.yaml.Table: 1 line
| Line | Points | Notes |
|---|---|---|
| Experiment | 363 |
Cycle life
review/revisions/panasonic/ncr18650pf-specification-3e3z6jtas-figures.yaml.Table: 1 line
| Line | Points | Notes |
|---|---|---|
| 4A discharge | 18 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/panasonic/ncr18650pf-jiang-2026-vtac-lib.yaml.Table: 6 lines
| Line | Points | Notes |
|---|---|---|
| Cell3# | 4 | |
| Cell4# | 4 | |
| Cell5# | 4 | |
| Cell6# | 4 | |
| Cell7# | 4 | |
| Cell8# | 4 |
Temperature rise
Select a line to hide or show it; double-click to see it alone.
review/revisions/panasonic/ncr18650pf-specification-3e3z6jtas-figures.yaml.Table: 15 lines
| Line | Points | Notes |
|---|---|---|
| 2 A | 267 | |
| 2 A | 281 | |
| 2 A | 305 | |
| 4 A | 337 | |
| 4 A | 313 | |
| 4 A | 319 | |
| 6 A | 606 | |
| 6 A | 543 | |
| 6 A | 553 | |
| 8 A | 681 | |
| 8 A | 629 | |
| 8 A | 663 | |
| 10 A | 645 | |
| 10 A | 606 | |
| 10 A | 618 |
Select a line to hide or show it; double-click to see it alone.
review/revisions/panasonic/ncr18650pf-specification-3e3z6jtas-figures.yaml.Table: 2 lines
| Line | Points | Notes |
|---|---|---|
| 25 °C | 331 | |
| 0 °C | 332 |
review/digitisation/paper-10-3390-app142311320-fig6c-rise.json). Curves from this document are in review/revisions/panasonic/ncr18650pf-han-2024-applsci.yaml.Table: 1 line
| Line | Points | Notes |
|---|---|---|
| Experiment | 501 | hidden 2031–2066 s, 2072–2130 s, 5286–5324 s, 5430–5515 s, 5685–5779 s, spanned |
Specifications
Every value, with its conditions. 11 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.
Current and power
- Standard charge current
- 1,365 mA
- standard value. Not stated: temperature
Charging | CC-CV, Std. 1365mA, 4.2V, | 4.0 hrs
· page 1, NCR18650PF Specification (slide 1)
Density
- Specific energy
- 207 Wh/kg
- typical value. Not stated: rate, temperature
Gravimetric: | 207 Wh/kg
· page 1, NCR18650PF Specification (slide 1)- Energy density
- 577 Wh/L
- typical value. Not stated: rate, temperature
Energy density | Volumetric: | 577 Wh/l
· page 1, NCR18650PF Specification (slide 1)
Electrical
- Nominal voltage
- 3.6 V
- nominal value
Nominal voltage 3.6V
· page 1, NCR18650PF Specification (slide 1)- Capacity
- 2,700 mAh
- 20 °C · rated value. Not stated: rate, discharge cut-off voltage
Rated capacity(1) Min. 2700mAh | (1) At 20
· page 1, NCR18650PF Specification (slide 1)- Capacity
- 2,750 mAh
- 25 °C · minimum value. Not stated: rate, discharge cut-off voltage
Nominal | Min. 2750mAh | capacity(2) | (2) At 25
· page 1, NCR18650PF Specification (slide 1)- Capacity
- 2,900 mAh
- 25 °C · typical value. Not stated: rate, discharge cut-off voltage
capacity(2) | Typ. 2900mAh | (2) At 25
· page 1, NCR18650PF Specification (slide 1)- Charge cutoff voltage
- 4.2 V
- standard value
- Same passage as standard charge current · page 1, NCR18650PF Specification (slide 1)
Physical
- Mass
- 47 g
- maximum value
Weight (max.) | 47.0g
· page 1, NCR18650PF Specification (slide 1)- Diameter
- 18.5 mm
- maximum value
Dimensions | Max. 18.5 mm
· page 1, NCR18650PF Specification (slide 1)- Height
- 65.3 mm
- maximum value
Max. 65.3 mm
· page 1, NCR18650PF Specification (slide 1)
Thermal and safety
- Operating temperature, min
- 10 °C
- charge · minimum value. Not stated: temperature reference
Temperature | Charge: +10 to +45°C
· page 1, NCR18650PF Specification (slide 1)- Operating temperature, min
- −20 °C
- discharge · minimum value. Not stated: temperature reference
Discharge: -20 to +60°C
· page 1, NCR18650PF Specification (slide 1)- Operating temperature, max
- 45 °C
- charge · maximum value. Not stated: temperature reference
- Same passage as operating temperature, min · page 1, NCR18650PF Specification (slide 1)
- Operating temperature, max
- 60 °C
- discharge · maximum value. Not stated: temperature reference
- Same passage as operating temperature, min · page 1, NCR18650PF Specification (slide 1)
More documents
180 further values from 3 documents. Read from other documents for the same battery and kept apart from the values above, each with its own conditions and passage. A document independent of the maker gives its own findings, not the maker's ratings.
A journal article independent of the maker: Hassan, K., Siaw, F. L., Thio, T. H. G., Abir, M. P. A. K. (2026), Experimental Validation of an Adaptive Series-Parallel Recombination Battery-Balancing Architecture Using Second-Life Lithium-Ion Cells, Electronics 15(14): 3106 (2026-07-15): 20 values. Under CC BY 4.0: credit its authors when you reuse these values. Record file: review/revisions/panasonic/ncr18650pf-hassan-2026-electronics.yaml.
Electrical
- Capacity
- 2,420 mAh
- 20 °C · to 2.5 V · measured value. Not stated: rate
Cell characteristics of selected cells for the experiment.
· page 15, Second-life cell 1, Table 5 and Section 3.3- Capacity
- 2,405 mAh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 2, Table 5 and Section 3.3
- Capacity
- 2,365 mAh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 3, Table 5 and Section 3.3
- Capacity
- 2,384 mAh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 4, Table 5 and Section 3.3
- Capacity
- 2,371 mAh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 5, Table 5 and Section 3.3
- Energy
- 8,598 mWh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 1, Table 5 and Section 3.3
- Energy
- 8,531 mWh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 2, Table 5 and Section 3.3
- Energy
- 8,392 mWh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 3, Table 5 and Section 3.3
- Energy
- 8,464 mWh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 4, Table 5 and Section 3.3
- Energy
- 8,391 mWh
- 20 °C · to 2.5 V · measured value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 5, Table 5 and Section 3.3
Impedance
- DC internal resistance
- 22 mΩ
- 20 °C · measured value. Not stated: pulse duration, pulse current, state of charge, direction
- Same passage as capacity · page 15, Second-life cell 1, Table 5 and Section 3.3
- DC internal resistance
- 22 mΩ
- 20 °C · measured value. Not stated: pulse duration, pulse current, state of charge, direction
- Same passage as capacity · page 15, Second-life cell 2, Table 5 and Section 3.3
- DC internal resistance
- 22 mΩ
- 20 °C · measured value. Not stated: pulse duration, pulse current, state of charge, direction
- Same passage as capacity · page 15, Second-life cell 3, Table 5 and Section 3.3
- DC internal resistance
- 22 mΩ
- 20 °C · measured value. Not stated: pulse duration, pulse current, state of charge, direction
- Same passage as capacity · page 15, Second-life cell 4, Table 5 and Section 3.3
- DC internal resistance
- 22 mΩ
- 20 °C · measured value. Not stated: pulse duration, pulse current, state of charge, direction
- Same passage as capacity · page 15, Second-life cell 5, Table 5 and Section 3.3
Lifetime
- State of health
- 90 %
- 20 °C · to 2.5 V · discharge · calculated value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 1, Table 5 and Section 3.3, calculated from discharge capacity
- State of health
- 89 %
- 20 °C · to 2.5 V · discharge · calculated value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 2, Table 5 and Section 3.3, calculated from discharge capacity
- State of health
- 88 %
- 20 °C · to 2.5 V · discharge · calculated value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 3, Table 5 and Section 3.3, calculated from discharge capacity
- State of health
- 88 %
- 20 °C · to 2.5 V · discharge · calculated value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 4, Table 5 and Section 3.3, calculated from discharge capacity
- State of health
- 88 %
- 20 °C · to 2.5 V · discharge · calculated value. Not stated: rate
- Same passage as capacity · page 15, Second-life cell 5, Table 5 and Section 3.3, calculated from discharge capacity
A dataset independent of the maker: Jiang, J. (2026), VTAC-LiB: A Variable-Temperature Aging and Characterization Dataset for Lithium-Ion Batteries, Zenodo (2026-11-05): 96 values. Under CC BY 4.0: credit its authors when you reuse these values. Record file: review/revisions/panasonic/ncr18650pf-jiang-2026-vtac-lib.yaml.
Electrical
- Capacity
- 2.3 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
two-stage 1C discharging separated by a rest interval
· Initial reference test. Cell3#/0-50cycles/0℃-calibration-3.csv, cycle 1- Capacity
- 2.49 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell3#/0-50cycles/10℃-calibration-3.csv, cycle 1
- Capacity
- 2.63 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell3#/0-50cycles/20℃-calibration-3.csv, cycle 1
- Capacity
- 2.7 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell3#/0-50cycles/30℃-calibration-3.csv, cycle 1
- Capacity
- 2.18 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell3#/51-100cycles/0℃-calibration-3.csv, cycle 1
- Capacity
- 2.34 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell3#/51-100cycles/10℃-calibration-3.csv, cycle 1
- Capacity
- 2.51 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell3#/51-100cycles/20℃-calibration-3.csv, cycle 1
- Capacity
- 2.11 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell3#/101-150cycles/0℃-calibration-3.csv, cycle 1
- Capacity
- 2.39 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell3#/101-150cycles/20℃-calibration-3.csv, cycle 1
- Capacity
- 2.6 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell3#/101-150cycles/40℃-calibration-3.csv, cycle 1
- Capacity
- 2.28 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell3#/151-200cycles/20℃-calibration-3.csv, cycle 1
- Capacity
- 2.42 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell3#/151-200cycles/30℃-calibration-3.csv, cycle 1
- Capacity
- 2.5 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell3#/151-200cycles/40℃-calibration-3.csv, cycle 1
- Capacity
- 2.05 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell3#/201-250cycles/10℃-calibration-3.csv, cycle 1
- Capacity
- 2.36 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell3#/201-250cycles/30℃-calibration-3.csv, cycle 1
- Capacity
- 2.45 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell3#/201-250cycles/40℃-calibration-3.csv, cycle 1
- Capacity
- 2.32 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell4#/0-50cycles/0℃-calibration-4.csv, cycle 1
- Capacity
- 2.5 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell4#/0-50cycles/10℃-calibration-4.csv, cycle 1
- Capacity
- 2.63 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell4#/0-50cycles/20℃-calibration-4.csv, cycle 1
- Capacity
- 2.71 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell4#/0-50cycles/30℃-calibration-4.csv, cycle 1
- Capacity
- 2.19 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell4#/51-100cycles/0℃-calibration-4.csv, cycle 1
- Capacity
- 2.34 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell4#/51-100cycles/10℃-calibration-4.csv, cycle 1
- Capacity
- 2.5 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell4#/51-100cycles/20℃-calibration-4.csv, cycle 1
- Capacity
- 2.07 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell4#/101-150cycles/0℃-calibration-4.csv, cycle 1
- Capacity
- 2.39 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell4#/101-150cycles/20℃-calibration-4.csv, cycle 1
- Capacity
- 2.59 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell4#/101-150cycles/40℃-calibration-4.csv, cycle 1
- Capacity
- 2.28 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell4#/151-200cycles/20℃-calibration-4.csv, cycle 1
- Capacity
- 2.42 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell4#/151-200cycles/30℃-calibration-4.csv, cycle 1
- Capacity
- 2.5 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell4#/151-200cycles/40℃-calibration-4.csv, cycle 1
- Capacity
- 2.11 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell4#/201-250cycles/10℃-calibration-4.csv, cycle 1
- Capacity
- 2.36 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell4#/201-250cycles/30℃-calibration-4.csv, cycle 1
- Capacity
- 2.44 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell4#/201-250cycles/40℃-calibration-4.csv, cycle 1
- Capacity
- 2.33 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell5#/0-50cycles/0℃-calibration-5.csv, cycle 1
- Capacity
- 2.51 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell5#/0-50cycles/10℃-calibration-5.csv, cycle 1
- Capacity
- 2.64 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell5#/0-50cycles/20℃-calibration-5.csv, cycle 1
- Capacity
- 2.72 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell5#/0-50cycles/30℃-calibration-5.csv, cycle 1
- Capacity
- 2.2 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell5#/51-100cycles/0℃-calibration-5.csv, cycle 1
- Capacity
- 2.38 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell5#/51-100cycles/10℃-calibration-5.csv, cycle 1
- Capacity
- 2.53 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell5#/51-100cycles/20℃-calibration-5.csv, cycle 1
- Capacity
- 2.18 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell5#/101-150cycles/0℃-calibration-5.csv, cycle 1
- Capacity
- 2.43 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell5#/101-150cycles/20℃-calibration-5.csv, cycle 1
- Capacity
- 2.62 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell5#/101-150cycles/40℃-calibration-5.csv, cycle 1
- Capacity
- 2.32 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell5#/151-200cycles/20℃-calibration-5.csv, cycle 1
- Capacity
- 2.46 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell5#/151-200cycles/30℃-calibration-5.csv, cycle 1
- Capacity
- 2.54 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell5#/151-200cycles/40℃-calibration-5.csv, cycle 1
- Capacity
- 2.11 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell5#/201-250cycles/10℃-calibration-5xlsx.csv, cycle 1
- Capacity
- 2.41 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell5#/201-250cycles/30℃-calibration-5.csv, cycle 1
- Capacity
- 2.49 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell5#/201-250cycles/40℃-calibration-5.csv, cycle 1
- Capacity
- 2.31 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell6#/0-50cycles/0℃-calibration-6.csv, cycle 1
- Capacity
- 2.5 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell6#/0-50cycles/10℃-calibration-6.csv, cycle 1
- Capacity
- 2.5 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell6#/0-50cycles/20℃-calibration-6.csv, cycle 1
- Capacity
- 2.72 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell6#/0-50cycles/30℃-calibration-6.csv, cycle 1
- Capacity
- 2.15 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell6#/51-100cycles/0℃-calibration-6.csv, cycle 1
- Capacity
- 2.33 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell6#/51-100cycles/10℃-calibration-6.csv, cycle 1
- Capacity
- 2.51 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell6#/51-100cycles/20℃-calibration-6.csv, cycle 1
- Capacity
- 2.07 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell6#/101-150cycles/0℃-calibration-6.csv, cycle 1
- Capacity
- 2.4 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell6#/101-150cycles/20℃-calibration-6.csv, cycle 1
- Capacity
- 2.62 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell6#/101-150cycles/40℃-calibration-6.csv, cycle 1
- Capacity
- 2.28 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell6#/151-200cycles/20℃-calibration-6.csv, cycle 1
- Capacity
- 2.44 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell6#/151-200cycles/30℃-calibration-6.csv, cycle 1
- Capacity
- 2.53 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell6#/151-200cycles/40℃-calibration-6.csv, cycle 1
- Capacity
- 2.08 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell6#/201-250cycles/10℃-calibration-6.csv, cycle 1
- Capacity
- 2.39 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell6#/201-250cycles/30℃-calibration-6.csv, cycle 1
- Capacity
- 2.48 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell6#/201-250cycles/40℃-calibration-6.csv, cycle 1
- Capacity
- 2.31 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell7#/0-50cycles/0℃-calibration-7.csv, cycle 1
- Capacity
- 2.49 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell7#/0-50cycles/10℃-calibration-7.csv, cycle 1
- Capacity
- 2.62 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell7#/0-50cycles/20℃-calibration-7.csv, cycle 1
- Capacity
- 2.7 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell7#/0-50cycles/30℃-calibration-7.csv, cycle 1
- Capacity
- 2.14 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell7#/51-100cycles/0℃-calibration-7.csv, cycle 1
- Capacity
- 2.32 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell7#/51-100cycles/10℃-calibration-7.csv, cycle 1
- Capacity
- 2.32 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell7#/51-100cycles/20℃-calibration-7.csv, cycle 1
- Capacity
- 2.04 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell7#/101-150cycles/0℃-calibration-7.csv, cycle 1
- Capacity
- 2.36 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell7#/101-150cycles/20℃-calibration-7.csv, cycle 1
- Capacity
- 2.57 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell7#/101-150cycles/40℃-calibration-7.csv, cycle 1
- Capacity
- 2.25 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell7#/151-200cycles/20℃-calibration-7.csv, cycle 1
- Capacity
- 2.38 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell7#/151-200cycles/30℃-calibration-7.csv, cycle 1
- Capacity
- 2.47 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell7#/151-200cycles/40℃-calibration-7.csv, cycle 1
- Capacity
- 2.01 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell7#/201-250cycles/10℃-calibration-7.csv, cycle 1
- Capacity
- 2.31 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell7#/201-250cycles/30℃-calibration-7.csv, cycle 1
- Capacity
- 2.39 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell7#/201-250cycles/40℃-calibration-7.csv, cycle 1
- Capacity
- 2.33 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell8#/0-50cycles/0℃-calibration-8.csv, cycle 1
- Capacity
- 2.52 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell8#/0-50cycles/10℃-calibration-8.csv, cycle 1
- Capacity
- 2.65 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell8#/0-50cycles/20℃-calibration-8.csv, cycle 1
- Capacity
- 2.73 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Initial reference test. Cell8#/0-50cycles/30℃-calibration-8.csv, cycle 1
- Capacity
- 2.21 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell8#/51-100cycles/0℃-calibration-8.csv, cycle 1
- Capacity
- 2.35 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell8#/51-100cycles/10℃-calibration-8.csv, cycle 1
- Capacity
- 2.52 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 50 ageing cycles. Cell8#/51-100cycles/20℃-calibration-8.csv, cycle 1
- Capacity
- 2.09 Ah
- 1 C · 0 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell8#/101-150cycles/0℃-calibration-8.csv, cycle 1
- Capacity
- 2.4 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell8#/101-150cycles/20℃-calibration-8.csv, cycle 1
- Capacity
- 2.62 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 100 ageing cycles. Cell8#/101-150cycles/40℃-calibration-8.csv, cycle 1
- Capacity
- 2.28 Ah
- 1 C · 20 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell8#/151-200cycles/20℃-calibration-8.csv, cycle 1
- Capacity
- 2.43 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell8#/151-200cycles/30℃-calibration-8.csv, cycle 1
- Capacity
- 2.52 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 150 ageing cycles. Cell8#/151-200cycles/40℃-calibration-8.csv, cycle 1
- Capacity
- 2.08 Ah
- 1 C · 10 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell8#/201-250cycles/10℃-calibration-8.csv, cycle 1
- Capacity
- 2.38 Ah
- 1 C · 30 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell8#/201-250cycles/30℃-calibration-8.csv, cycle 1
- Capacity
- 2.49 Ah
- 1 C · 40 °C chamber set-point · to 2.5 V · measured value
- Same passage as capacity · Aged cell after 200 ageing cycles. Cell8#/201-250cycles/40℃-calibration-8.csv, cycle 1
A journal article independent of the maker: Zhang, L., Mu, Z., Gao, X. (2018), Coupling Analysis and Performance Study of Commercial 18650 Lithium-Ion Batteries under Conditions of Temperature and Vibration, Energies 11(10): 2856 (2018-10-22): 64 values. Under CC BY 4.0: credit its authors when you reuse these values. Record file: review/revisions/panasonic/ncr18650pf-zhang-2018-energies.yaml.
Electrical
- Capacity
- 2.85 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
Eight NCR18650PF batteries were discharged at room temperature at constant current 0.1, 0.2, 1/3, 0.5, 1, 1.5 and 2 C-rates
· page 6, Table 1, row Cell 01, column 0.1C- Capacity
- 2.81 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 01, column 0.2C
- Capacity
- 2.75 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 01, column 1/3C
- Capacity
- 2.71 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 01, column 0.5C
- Capacity
- 2.73 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 01, column 1C
- Capacity
- 2.75 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 01, column 3/2C
- Capacity
- 2.78 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 01, column 2C
- Capacity
- 2.76 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 02, column 0.1C
- Capacity
- 2.78 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 02, column 0.2C
- Capacity
- 2.74 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 02, column 1/3C
- Capacity
- 2.72 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 02, column 0.5C
- Capacity
- 2.71 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 02, column 1C
- Capacity
- 2.73 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 02, column 3/2C
- Capacity
- 2.75 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 02, column 2C
- Capacity
- 2.8 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 03, column 0.1C
- Capacity
- 2.81 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 03, column 0.2C
- Capacity
- 2.78 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 03, column 1/3C
- Capacity
- 2.75 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 03, column 0.5C
- Capacity
- 2.75 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 03, column 1C
- Capacity
- 2.77 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 03, column 3/2C
- Capacity
- 2.78 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 03, column 2C
- Capacity
- 2.82 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 04, column 0.1C
- Capacity
- 2.79 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 04, column 0.2C
- Capacity
- 2.73 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 04, column 1/3C
- Capacity
- 2.69 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 04, column 0.5C
- Capacity
- 2.71 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 04, column 1C
- Capacity
- 2.73 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 04, column 3/2C
- Capacity
- 2.74 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 04, column 2C
- Capacity
- 2.76 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 05, column 0.1C
- Capacity
- 2.78 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 05, column 0.2C
- Capacity
- 2.75 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 05, column 1/3C
- Capacity
- 2.73 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 05, column 0.5C
- Capacity
- 2.72 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 05, column 1C
- Capacity
- 2.74 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 05, column 3/2C
- Capacity
- 2.75 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 05, column 2C
- Capacity
- 2.83 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 06, column 0.1C
- Capacity
- 2.79 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 06, column 0.2C
- Capacity
- 2.76 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 06, column 1/3C
- Capacity
- 2.75 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 06, column 0.5C
- Capacity
- 2.74 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 06, column 1C
- Capacity
- 2.75 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 06, column 3/2C
- Capacity
- 2.77 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 06, column 2C
- Capacity
- 2.79 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 07, column 0.1C
- Capacity
- 2.81 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 07, column 0.2C
- Capacity
- 2.77 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 07, column 1/3C
- Capacity
- 2.74 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 07, column 0.5C
- Capacity
- 2.74 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 07, column 1C
- Capacity
- 2.76 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 07, column 3/2C
- Capacity
- 2.78 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 07, column 2C
- Capacity
- 2.79 Ah
- 0.1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 08, column 0.1C
- Capacity
- 2.81 Ah
- 0.2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 08, column 0.2C
- Capacity
- 2.78 Ah
- C/3 · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 08, column 1/3C
- Capacity
- 2.75 Ah
- 0.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 08, column 0.5C
- Capacity
- 2.75 Ah
- 1 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 08, column 1C
- Capacity
- 2.78 Ah
- 1.5 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 08, column 3/2C
- Capacity
- 2.79 Ah
- 2 C · measured value. Not stated: temperature, discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 6, Table 1, row Cell 08, column 2C
- Capacity
- 2.45 Ah
- 1 C · -15 °C chamber set-point · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
Table 3 shows the discharge capacity of four batteries in a low temperature environment and two batteries in a room temperature environment obtained under a constant current discharge at a 1 C rate.
· page 11, Table 3, column Cell 9, row 'discharge capacity'- Capacity
- 2.45 Ah
- 1 C · -15 °C chamber set-point · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 11, Table 3, column Cell 10, row 'discharge capacity'
- Capacity
- 2.45 Ah
- 1 C · -15 °C chamber set-point · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 11, Table 3, column Cell 11, row 'discharge capacity'
- Capacity
- 2.42 Ah
- 1 C · -15 °C chamber set-point · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 11, Table 3, column Cell 12, row 'discharge capacity'
- Capacity
- 2.43 Ah
- 1 C · -15 °C chamber set-point · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 11, Table 3, column Cell 13, row 'discharge capacity'
- Capacity
- 2.44 Ah
- 1 C · -15 °C chamber set-point · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 11, Table 3, column Cell 14, row 'discharge capacity'
- Capacity
- 2.7 Ah
- 1 C · 18 °C · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 11, Table 3, column Cell 15, row 'discharge capacity'
- Capacity
- 2.73 Ah
- 1 C · 18 °C · measured value. Not stated: discharge cut-off voltage, capacity the rate refers to
- Same passage as capacity · page 11, Table 3, column Cell 16, row 'discharge capacity'
Source and dates
One document behind every value. Each value above is read from it, and quoted where the record holds the passage.
- Kind
- datasheet
- SHA-256
860b056932221acced2557718dc2ab430828a3f6edec3c1bba0161b0275995aa- Note
- Five-slide Panasonic specification for the NCR18650PF (Panasonic logo on every slide, footer code 3E3Z6JTAS), hosted by the Slovenian retailer akumulator.si, not by Panasonic. No revision or issue date is printed. Footnotes on slide 1: (1) At 20°C (2) At 25°C (3) Energy density is calculated using bare cell dimensions (without tube). Table cells are joined with ' | ' in locator quotes. No chemistry is stated, so none is recorded. Printed but not recorded: storage temperature, the 4.0 hrs charging time, and the discharge (by rate and temperature) and 4A cycle-life curves on slides 2-5.
- Source document date
- Not recorded (evidence)
- Source revision
- Not recorded
- Specification source retrieved
- 2026-11-11 (day precision) (evidence)
- Product lifecycle checked
- Not recorded
- Product release
- Not researched
- Date context
- Source retrieval and document revision do not establish product release or current availability.
- Record id
cell/panasonic/ncr18650pf
How to cite
Panasonic. “Panasonic NCR18650PF Specification (5 slides, footer code 3E3Z6JTAS)”, datasheet. https://www.akumulator.si/images/products/ncr18650pf.pdf (retrieved 2026-11-11). Values as compiled in the Lemonergy battery library, record cell/panasonic/ncr18650pf: https://lemonergy.com/data/batteries/panasonic/ncr18650pf/
The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library
Suppliers of this product
No supplier has listed this product yet. Do you supply it? Write to [email protected].
Similar batteries
Compare it with these. Nearest in the library by kind, format, chemistry, capacity and specific energy.
- Samsung SDI INR18650-29E2.75 Ah lithium-ion cylindrical cell · 3.65 V · 209 Wh/kgView the page
- Samsung SDI ICR18650-26J2.55 Ah lithium-ion cylindrical cell · 3.63 V · 206 Wh/kgView the page
- Samsung SDI ICR18650-26C2.6 Ah lithium-ion cylindrical cell · 3.7 V · 205 Wh/kgView the page
- Samsung SDI INR18650-25R2.5 Ah cylindrical cell · 3.6 V · 200 Wh/kgView the page
- Samsung SDI ICR18650-26H2.6 Ah lithium-ion cylindrical cell · 3.63 V · 201 Wh/kgView the page
- LG Chem INR18650 B42.6 Ah lithium-ion cylindrical cell · 3.6 V · 195 Wh/kgView the page