EVE Energy MB56
628 Ah LFP prismatic cell.
Every value read from the datasheet (dated 2023), with the conditions it was stated at.
Compare in the finderSource documentRecord as JSON (API)Report a correction
- Capacity1
- 628Ah
- Nominal voltage
- 3.2V
- Energy2
- 2,010Wh
- Mass
- 11.5kg
- Specific energy3
- 175Wh/kg
- Energy density4
- 384Wh/L
- Dimensions
- 207.2 × 352.3 × 71.7mm
- Cycle life5
- 8,000cycles
- Internal resistance
- 0.1mΩ
- Operating temperature6
- −30 to 60°C
- 1Capacity: 0.5 P · 25 °C · to 2.5 V.
- 2Energy: 0.5 P · 25 °C · to 2.5 V.
- 3Specific energy: calculated by Lemonergy from stated values.
- 4Energy density: calculated by Lemonergy from stated values.
- 5Cycle life: 0.5 P · 25 °C · to 2.5 V.
- 6Operating temperature: discharge; charge 0 to 60 °C.
- Not stated by the source: continuous discharge.
Specifications
Every value, with its conditions. 30 quantities stated by the datasheet, grouped as in the finder. Conditions are the rate, temperature and limits each value was stated at.
Current and power
- Charge power rate (P), standard
- 0.5 P
- 25 °C · standard value
Standard Charging Power | 0.5P | 25℃ ± 2℃
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Discharge power rate (P), standard
- 0.5 P
- 25 °C · standard value
Standard Discharging Power | 0.5P | 25℃ ± 2℃
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Charge power rate (P), maximum
- 0.5 P
- 25 °C · maximum value
Max. Continuous Charging Power | 0.5P | 25℃ ± 2℃
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Charge power rate (P), maximum
- 0.05 P
- 0 °C cell surface · maximum value
Table 5 Continuous Charging Modes (unit: P-Rate) | Cell temperature /℃ | 0 5 10 15 20 25 45 50 55 60 | Max charging | power | 0% ~ 100% | SOC | 0.05 0.12 0.3 0.5 0.5 0.5 0.5 0.5 0.5 0
· page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 0℃- Charge power rate (P), maximum
- 0.12 P
- 5 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 5℃
- Charge power rate (P), maximum
- 0.3 P
- 10 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 10℃
- Charge power rate (P), maximum
- 0.5 P
- 15 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 15℃
- Charge power rate (P), maximum
- 0.5 P
- 20 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 20℃
- Charge power rate (P), maximum
- 0.5 P
- 25 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 25℃
- Charge power rate (P), maximum
- 0.5 P
- 45 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 45℃
- Charge power rate (P), maximum
- 0.5 P
- 50 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 50℃
- Charge power rate (P), maximum
- 0.5 P
- 55 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 55℃
- Charge power rate (P), maximum
- 0 P
- 60 °C cell surface · maximum value
- Same passage as charge power rate (p), maximum · page 11, 2.3.2 Other Charging Modes, Table 5 Continuous Charging Modes (unit: P-Rate) (PDF page 11, printed page 4), column 60℃
- Discharge power rate (P), maximum
- 0.5 P
- 25 °C · maximum value
Max. Continuous Discharging Power | 0.5P | 25℃ ± 2℃
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Discharge power rate (P), maximum
- 0 P
- -30 °C cell surface · maximum value
Table 7 Continuous Discharging Rate (unit: P-Rate) | Cell temperature /℃ | -30 -20 -10 -5 0 5 45 50 55 60 | Max discharging power | 0% ~ 100% | SOC | 0 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0
· page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column -30℃- Discharge power rate (P), maximum
- 0.5 P
- -20 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column -20℃
- Discharge power rate (P), maximum
- 0.5 P
- -10 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column -10℃
- Discharge power rate (P), maximum
- 0.5 P
- -5 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column -5℃
- Discharge power rate (P), maximum
- 0.5 P
- 0 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column 0℃
- Discharge power rate (P), maximum
- 0.5 P
- 5 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column 5℃
- Discharge power rate (P), maximum
- 0.5 P
- 45 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column 45℃
- Discharge power rate (P), maximum
- 0.5 P
- 50 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column 50℃
- Discharge power rate (P), maximum
- 0.5 P
- 55 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column 55℃
- Discharge power rate (P), maximum
- 0 P
- 60 °C cell surface · maximum value
- Same passage as discharge power rate (p), maximum · page 12, 2.4.2 Other Discharging Modes, Table 7 Continuous Discharging Rate (unit: P-Rate) (PDF page 12, printed page 5), column 60℃
Electrical
- Nominal voltage
- 3.2 V
- nominal value
Nominal Voltage | 3.2 V
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Capacity
- 628 Ah
- 0.5 P · 25 °C · to 2.5 V · nominal value
Nominal Capacity | 628 Ah | 0.5P / 0.5P, 25℃ ± 2℃, 2.5 V ~ 3.65 V | Fresh cell
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Charge cutoff voltage
- 3.65 V
- Conditions not given
End-of-charge Voltage (Umax) | 3.65 V
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Discharge cutoff voltage
- 2.5 V
- temperature > 0 °C
End-of-discharge Voltage (Umin) | 2.5 V T >0℃ | 2.0 V T ≤0℃
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Discharge cutoff voltage
- 2 V
- temperature ≤ 0 °C
- Same passage as discharge cutoff voltage · page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)
- Absolute max voltage
- 3.8 V
- absolute maximum value
Absolute charging voltage | Max 3.8 V | No matter what charging mode the cell is in, once the | cell voltage exceeds the absolute charging voltage, stop
· page 11, 2.3.1 Charging Mode, Table 4 Charging Mode Parameters, continued (PDF page 11, printed page 4)- Absolute min voltage
- 1.8 V
- absolute minimum value
Absolute discharging voltage | Min 1.8 V | No matter what kind of discharging mode the cell is on, once the | cell voltage is less than the absolute discharge voltage, stop
· page 12, 2.4.1 Discharging Mode, Table 6 Discharging Mode Parameter, continued (PDF page 12, printed page 5)- Energy
- 2,010 Wh
- 0.5 P · 25 °C · to 2.5 V · nominal value
Nominal Energy | 2009.6 Wh | 0.5P / 0.5P, 25℃ ± 2℃, 2.5 V ~ 3.65 V | Fresh cell
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)
Impedance
- AC internal resistance
- 0.1 mΩ
- 25 °C · 1000 Hz · initial value. Not stated: state of charge
Initial Internal Resistance | 0.10 mΩ | 0.05 mΩ | AC, 1 kHz, Delivery SOC, | Fresh cell
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)
Lifetime
- Cycle life
- 8,000 cycles
- 0.5 P · 25 °C · to 2.5 V. Not stated: depth of discharge
Cycle Life | 25℃ Cycle | 8000 cycles, 70% SOH | Appendix 1.15
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Energy retention
- ≥ 95 %
- 1 P · 25 °C · to 2.5 V · minimum value. Not stated: cycle index
Rate Charge and | Discharge Performance | 1P | E2* ≥ 95%*E1* | Appendix 1.11
· page 9, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters (PDF page 9, printed page 2)- Energy retention
- ≥ 98 %
- 0.5 P · 45 °C · to 2.5 V · minimum value. Not stated: cycle index
High/Low Temperature | 45℃ | E4 ≥ 98%*E0 | Appendix 1.12
· page 9, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters (PDF page 9, printed page 2)- Energy retention
- ≥ 80 %
- 0.5 P · 5 °C · to 2.5 V · minimum value. Not stated: cycle index
High/Low Temperature | 5℃ | E5* ≥ 80%*E0* | Appendix 1.12
· page 9, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters (PDF page 9, printed page 2)- Energy retention
- ≥ 95 %
- 0.5 P · 25 °C · to 2.5 V · 100 % SoC · minimum value. Not stated: cycle index
100% SOC | 25℃ & 28 days | E6* ≥ 95%*E0*
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Energy retention
- ≥ 95 %
- 0.5 P · 45 °C · to 2.5 V · 100 % SoC · minimum value. Not stated: cycle index
100% SOC | 45℃ & 7 days | E8* ≥ 95%*E0*
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Energy recovery
- ≥ 97 %
- 0.5 P · 25 °C · to 2.5 V · 100 % SoC · minimum value
100% SOC | 25℃ & 28 days | E7* ≥ 97%*E0*
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Energy recovery
- ≥ 97 %
- 0.5 P · 45 °C · to 2.5 V · 100 % SoC · minimum value
100% SOC | 45℃ & 7 days | E9* ≥ 97%*E0*
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Energy recovery
- ≥ 98 %
- 0.5 P · 25 °C · to 2.5 V · 50 % SoC · minimum value
Storage | 50% SOC | 25℃ & 28days | ≥ 98%*E0* | Appendix 1.14
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Energy recovery
- ≥ 97 %
- 0.5 P · 45 °C · to 2.5 V · 50 % SoC · minimum value
Storage | 50% SOC | 45℃ & 28days | ≥ 97%*E0* | Appendix 1.14
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Self discharge rate
- ≤ 3.5 %/month
- 25 °C · maximum value. Not stated: state of charge, duration
Self-discharge | First Month | 3.5% / M | Delivery SOC status, 25°C ± 2°C | storage
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)- Self discharge rate
- ≤ 3 %/month
- 25 °C · maximum value. Not stated: state of charge, duration
Self-discharge | After First Month | 3.0% / M | Delivery SOC status, 25°C ± 2°C | storage
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)- Energy efficiency
- ≥ 94 %
- 0.5 P · 25 °C · to 2.5 V · charge and discharge · minimum value
Rate Charge and | Discharge Performance | 0.5P | E1*/E1 ≥ 94% | Appendix 1.11
· page 9, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters (PDF page 9, printed page 2)- Energy efficiency
- ≥ 90 %
- 1 P · 25 °C · to 2.5 V · charge and discharge · minimum value
Rate Charge and | Discharge Performance | 1P | E3*/E3 ≥ 90% | Appendix 1.11
· page 9, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters (PDF page 9, printed page 2)- Energy efficiency
- ≥ 95 %
- 0.5 P · 45 °C · to 2.5 V · charge and discharge · minimum value
High/Low Temperature | 45℃ | E4 /E4 ≥ 95% | Appendix 1.12
· page 9, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters (PDF page 9, printed page 2)- Energy efficiency
- ≥ 80 %
- 0.5 P · 5 °C · to 2.5 V · charge and discharge · minimum value
High/Low Temperature | 5℃ | E5*/E5 ≥ 80% | Appendix 1.12
· page 9, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters (PDF page 9, printed page 2)
Mechanical
- Expansion force
- ≤ 45,000 N
- maximum value. Not stated: state of charge, constraint mode
Swelling Force | 70% SOH | ≤ 45000 N | Appendix 1.16
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Expansion force
- ≤ 55,000 N
- maximum value. Not stated: state of charge, constraint mode
Swelling Force | 60% SOH | ≤ 55000 N | Appendix 1.16
· page 10, 2.2 Electrical Performance, Table 3 Electrical Performance Parameters, continued (PDF page 10, printed page 3)- Expansion force
- 60,000 N
- typical value. Not stated: state of charge
the expansion force is about 60000 N when the cell capacity attenuates to 60% under the | test conditions of 15 mm steel plate + 0.0 mm GAP (the space for cells to expand)
· page 18, 4.7 Cell Swelling Force (PDF pages 18-19, printed pages 11-12: the quote runs from the foot of page 18 onto page 19)
Physical
- Mass
- 11,500 g
- nominal value
Weight | 11500 g ± 300 g
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Height
- 207.2 mm
- nominal value
Dimensions | (With | Height1 | 207.2 mm ± 0.5 mm | With Terminal
· page 8, 2.1 Product Specifications, Table 2 Product Specifications (PDF page 8, printed page 1)- Width
- 352.3 mm
- nominal value
insulation film) | Length | 352.3 mm ± 0.5 mm
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)- Thickness
- 71.7 mm
- nominal value
Thickness | 71.7 mm ± 0.5 mm | (300 kgf ± 20 kgf compression force, | Delivery SOC)
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)
Thermal and safety
- Operating temperature, min
- 0 °C
- charge · minimum value. Not stated: temperature reference
Charging Temperature | Operation | Temperature | 0℃ ~ 60℃
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)- Operating temperature, min
- −30 °C
- discharge · minimum value. Not stated: temperature reference
Discharging Temperature | -30℃ ~ 60℃
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)- Operating temperature, min
- 0 °C
- charge · cell surface temperature · minimum value
Absolute charging | temperature (cell | temperature) | 0℃ ~ 60℃ | No matter what charging mode the cell is in, once the | cell temperature exceeds the absolute charging | temperature range, stop charging.
· page 11, 2.3.1 Charging Mode, Table 4 Charging Mode Parameters, continued (PDF page 11, printed page 4)- Operating temperature, min
- −35 °C
- discharge · cell surface temperature · minimum value
Absolute discharging | temperature (cell | temperature) | -35℃ ~ 65℃ | No matter what discharging mode the cell is on, once the cell | temperature exceeds the absolute discharge temperature range, stop
· page 12, 2.4.1 Discharging Mode, Table 6 Discharging Mode Parameter, continued (PDF page 12, printed page 5)- Operating temperature, min
- 10 °C
- minimum value. Not stated: temperature reference, direction
Recommended operating | temperature range | 10℃ ~ 45℃ | Recommended cell using temperature range
· page 16, 4.4 BMS design, Table 10 Safety Limit Temperature Parameters (PDF page 16, printed page 9)- Operating temperature, min
- −30 °C
- minimum value. Not stated: temperature reference, direction
Minimum operating | temperature | -30 C | If the cell temperature exceeds the minimum operating | temperature, the cell power needs to be reduced to 0.
· page 16, 4.4 BMS design, Table 10 Safety Limit Temperature Parameters (PDF page 16, printed page 9)- Operating temperature, min
- −35 °C
- absolute minimum value. Not stated: temperature reference, direction
Minimum safe | temperature | -35℃ | If the battery temperature exceeds the minimum safe temperature, | it will cause irreversible and permanent damage to the battery
· page 16, 4.4 BMS design, Table 10 Safety Limit Temperature Parameters (PDF page 16, printed page 9)- Operating temperature, max
- 60 °C
- charge · maximum value. Not stated: temperature reference
- Same passage as operating temperature, min · page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)
- Operating temperature, max
- 60 °C
- discharge · maximum value. Not stated: temperature reference
- Same passage as operating temperature, min · page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)
- Operating temperature, max
- 60 °C
- charge · cell surface temperature · maximum value
- Same passage as operating temperature, min · page 11, 2.3.1 Charging Mode, Table 4 Charging Mode Parameters, continued (PDF page 11, printed page 4)
- Operating temperature, max
- 65 °C
- discharge · cell surface temperature · maximum value
- Same passage as operating temperature, min · page 12, 2.4.1 Discharging Mode, Table 6 Discharging Mode Parameter, continued (PDF page 12, printed page 5)
- Operating temperature, max
- 45 °C
- maximum value. Not stated: temperature reference, direction
- Same passage as operating temperature, min · page 16, 4.4 BMS design, Table 10 Safety Limit Temperature Parameters (PDF page 16, printed page 9)
- Operating temperature, max
- 60 °C
- maximum value. Not stated: temperature reference, direction
Maximum operating | temperature | 60℃ | If the cell temperature exceeds the maximum operating | temperature, the cell power needs to be reduced to 0.
· page 16, 4.4 BMS design, Table 10 Safety Limit Temperature Parameters (PDF page 16, printed page 9)- Operating temperature, max
- 65 °C
- absolute maximum value. Not stated: temperature reference, direction
Maximum safe | temperature | 65℃ | If the battery temperature exceeds the maximum safe temperature, | it will cause irreversible and permanent damage to the battery
· page 16, 4.4 BMS design, Table 10 Safety Limit Temperature Parameters (PDF page 16, printed page 9)- Storage temperature min
- 0 °C
- minimum value. Not stated: duration
Storage | Temperature | 1 year | 0℃ ~ 35℃ | Delivery SOC status
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)- Storage temperature min
- −20 °C
- minimum value. Not stated: duration
Storage | Temperature | 1 month | -20℃ ~ 45℃ | Delivery SOC status
· page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)- Storage temperature min
- 0 °C
- minimum value. Not stated: duration
If long-term storage is required, adjust the cell SOC to 30% ~ 40%. | The recommended storage conditions are: 0℃ ~ 25℃, | relative humidity ≤ 60%.
· page 19, 4.9 Storage (PDF page 19, printed page 12)- Storage temperature max
- 35 °C
- maximum value. Not stated: duration
- Same passage as storage temperature min · page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)
- Storage temperature max
- 45 °C
- maximum value. Not stated: duration
- Same passage as storage temperature min · page 9, 2.1 Product Specifications, Table 2 Product Specifications, continued (PDF page 9, printed page 2)
- Storage temperature max
- 25 °C
- maximum value. Not stated: duration
- Same passage as storage temperature min · page 19, 4.9 Storage (PDF page 19, printed page 12)
- Specific heat capacity
- 0.9 kJ/(kg·K)
- minimum value. Not stated: state of charge, temperature
Mean heat capacity | Heat Capacity | (kJ/(kg·K)) | 0.9 ~ 1.1 kJ/(kg·K)
· page 19, 4.8 Recommended Temperature Control, Table 14 Cell Thermal Conductivity Parameters (PDF page 19, printed page 12)- Specific heat capacity
- 1.1 kJ/(kg·K)
- maximum value. Not stated: state of charge, temperature
- Same passage as specific heat capacity · page 19, 4.8 Recommended Temperature Control, Table 14 Cell Thermal Conductivity Parameters (PDF page 19, printed page 12)
- Thermal conductivity in plane
- 9 W/(m·K)
- minimum value. Not stated: temperature
Mean thermal conductivity | Thermal Conductivity W/(m·K) | X/Z direction | 9 ~ 11 W/(m·K)
· page 19, 4.8 Recommended Temperature Control, Table 14 Cell Thermal Conductivity Parameters (PDF page 19, printed page 12)- Thermal conductivity in plane
- 11 W/(m·K)
- maximum value. Not stated: temperature
- Same passage as thermal conductivity in plane · page 19, 4.8 Recommended Temperature Control, Table 14 Cell Thermal Conductivity Parameters (PDF page 19, printed page 12)
- Thermal conductivity through plane
- 2 W/(m·K)
- minimum value. Not stated: temperature
Mean thermal conductivity | Thermal Conductivity W/(m·K) | Y direction | 2 ~ 3 W/(m·K)
· page 19, 4.8 Recommended Temperature Control, Table 14 Cell Thermal Conductivity Parameters (PDF page 19, printed page 12)- Thermal conductivity through plane
- 3 W/(m·K)
- maximum value. Not stated: temperature
- Same passage as thermal conductivity through plane · page 19, 4.8 Recommended Temperature Control, Table 14 Cell Thermal Conductivity Parameters (PDF page 19, printed page 12)
Other recorded quantities
- State of charge
- 30 %
- minimum value
If long-term storage is required, adjust the cell SOC to 30% ~ 40%.
· page 19, 4.9 Storage (PDF page 19, printed page 12)- State of charge
- 40 %
- maximum value
- Same passage as state of charge · page 19, 4.9 Storage (PDF page 19, printed page 12)
- State of charge
- 15 %
- minimum value
4.10 The state of charge (SOC, capacity state) of the cell should be kept at 15% ~ 40% during storage.
· page 20, 4.10 Storage (PDF page 20, printed page 13)- State of charge
- 40 %
- maximum value
- Same passage as state of charge · page 20, 4.10 Storage (PDF page 20, printed page 13)
Chemistry
What it is made of. Classified as Lithium-ion · LFP.
- Classified as
- Lithium-ion · LFP
- Designation
- LFP
- Cathode
- LFP
Sample Specification | Prismatic LFP Cell | Model: MB56
Source and dates
One document behind every value. Each value above is read from it, and quoted where the record holds the passage.
- Kind
- datasheet
- SHA-256
77b4b33329f0bf0be217a0cb90643491704c2d31af4eb22eb1dffe8f12fe28b6- Note
- EVE Power Co., Ltd.'s 39-page bilingual (English and Chinese) 'Sample Specification, Prismatic LFP Cell, Model: MB56', Specification No. PBRI-MB56-D06-01, Version A; the library files EVE's cells under the maker name EVE Energy. The revision history lists only Version A, 2023.11.23, 'First issue, sample delivery' (cover: Nov. 2023); that date is the document date. It is a sample specification, not a mass-production one, so it is marked as not final. This is EVE's document as hosted on a distributor's website, not by EVE: the file was re-written by Ghostscript in 2025, so it is a copy of EVE's specification, not EVE's own export. The address served these 1,684,833 bytes on 2026-11-18. Only extracted facts, the URL and the hash are stored here. Locator pages are PDF pages; printed page numbers (i to vi, then 1 to 32 from PDF page 8) are given in each section. Quotes are from the PDF text layer, English cells of one table row joined with ' | '. This copy draws most Chinese text as images, so the Chinese duplicates are left out of quotes; a few signs drawn the same way (the ± of the AC resistance, the ≤ of the self-discharge) were read on the rendered pages, and the Chinese labels were read there and agree with the English ones. The document says the Chinese version prevails (6 Disclaimer). 'P' is EVE's power rate (Term Definition, 'Power'): the charge or discharge power divided by the cell energy the battery system measures, so 0.5P is 1004.8 W for 2009.6 Wh. It is not a C-rate and is never converted; P values are filed in the library's P-rate quantities. Tests are at 25℃ ± 2℃ unless stated otherwise (Appendix 2, 1.1). Cell temperature is measured by a sensor at the center of the cell surface (Term Definition), filed as temperature_reference cell_surface where a limit is stated in cell temperature (Tables 4 to 7); Table 2 and Table 10 do not say where their temperatures are taken (Table 10's Chinese remarks, which prevail, say 电池使用温度, a term the document does not define), and that is listed as unstated. Filed: Table 2 (capacity, energy, voltages, with the discharge cut-offs' temperature band, the four 0.5P power rates, initial AC resistance, weight, dimensions, operation and storage temperatures, self-discharge); Table 3 (energy efficiency at 0.5P, 1P, 45℃ and 5℃; energy retention, measured before any recharge, at 1P, 45℃ and 5℃ and after storage at 100% SOC; energy recovery, measured after storage and a full recharge, at 100% and 50% SOC; cycle life; swelling force); Tables 4 and 6 (absolute charging and discharging temperatures and voltages); Tables 5 and 7 (maximum charging and discharging power by cell temperature, 0% ~ 100% SOC, one value per column); Table 10 (recommended, operating and safe temperatures); Table 14 (thermal conductivity in the X/Z and Y directions and heat capacity, printed ranges filed as a minimum and a maximum); 4.7 (swelling force of about 60000 N at 60% SOH, filed as typical); 4.9 and 4.10 (recommended storage temperature and storage SOC). Height2 (H2), 205.1 mm ± 0.5 mm without the terminals, is kept in the conditions of the 207.2 mm height (H1, with the terminals) and not filed as a second height, because a second height in an accepted record would replace H1 in the finder's dimensions. Values that Tables 4 and 6 repeat from Table 2 are filed once. Contradiction, both filed as printed: at 60% SOH Table 3 gives a swelling force of ≤ 55000 N (Appendix 1.16 clamp) and 4.7 about 60000 N (15 mm steel plate + 0.0 mm GAP). Printed and not filed (no quantity in the library): the centre distance between the poles 180.0 mm ± 0.3 mm (Table 2); the cell temperature rise ≤ 10℃ in a 0.5P discharge at 25℃ (Table 3); the safety tests of Table 8 (pass criteria) and their test conditions (Appendix 1.17); end of life when the internal resistance exceeds 150% of its initial value or the capacity falls below 60% of nominal (3); the BMS voltage thresholds of Table 9 (charging 3.65, 3.7, 3.75 and 3.80 V; discharging 2.5/2.0, 2.0/1.9, 1.9/1.8 and 1.85/1.75 V above/at or below 0℃) and its charging capacity limit < 709.64 Ah (113% of nominal); the welding recommendations of Table 11 (laser welding depth ≤ 2.0 mm, 500 N and 6 N·m on the poles, poles up to 130℃, 1~2 welding rings); the compression force of Table 13 (recommended 3000 N ~ 7000 N, instantaneous maximum ≤ 10000 N) and its test conditions (4.6); the expansion space of 2.0 mm ~ 2.5 mm (4.7); the storage advice of 4.9 and 4.10 (relative humidity ≤ 60%; in storage of more than three months, a standard charge-discharge cycle every 3 months; no more than half a year of storage after receipt); keeping the voltage above 2.8 V (5). The DC resistance is defined (Appendix 2, 1.6 b) but no value is printed. Figures: the document's nine figures (Fig. 1 to 7, the test clamps, the crush device and the thermal-runaway set-up; Fig. 12, the cell's axes; Fig. 15, the dimension drawing) are drawings and renderings; none plots data, so nothing is digitised and no model is fitted. Fig. 15 repeats the dimensions of Table 2 in its layout; its labels are too small to read reliably at this copy's image resolution, so nothing is read from it. A second copy, supplied to Lemonergy by a commercial partner on 2026-11-18, was compared page by page and is not used: its tables and figures are the same, but four numbers in two worked examples of the Term Definition differ (1004.8 Wh for 2009.6 Wh and 803.47 W for 803.84 W under 'Power', 1004.8 Ah for 502.4 Ah at 80% SOH under 'State of health'); this copy's are the consistent ones (628 Ah × 3.2 V = 2009.6 Wh; 80% of 628 Ah = 502.4 Ah). The 352.3 mm side, 'Length (L)' in English and 宽度 (width) in Chinese, is filed as width, the library's quantity for a prismatic cell's long side. form_factor 'prismatic_hardcase' is the library's classification of the 'prismatic aluminum shell' the Term Definition names. These are manufacturer claims, not independent lab measurements.
- Source document date
- 2023-11-23 (day precision) (evidence)
- Source revision
- A
- Specification source retrieved
- 2026-11-18 (day precision) (evidence)
- Product lifecycle checked
- Not recorded
- Product release
- Not researched
- Date context
- Source retrieval and document revision do not establish product release or current availability.
- Record id
cell/eve/mb56
How to cite
EVE Energy. “EVE Power Co., Ltd. Sample Specification, Prismatic LFP Cell, Model MB56, Specification No. PBRI-MB56-D06-01, Version A”, datasheet, A, 2023-11-23. https://lifepo4.com.au/wp-content/uploads/2025/06/EVE-MB56.pdf (retrieved 2026-11-18). Values as compiled in the Lemonergy battery library, record cell/eve/mb56: https://lemonergy.com/data/batteries/eve/mb56/
The values are CC BY 4.0; the document and the passages quoted from it belong to its publisher. All sources of the library
Suppliers of this product
| Supplier | Country | Stock | Minimum order | Lead time | Offer stated | Contact |
|---|---|---|---|---|---|---|
| JLi Energy (opens in a new tab) | CN | Poland, Spain and Shenzhen | 1 carton from EU stock | — | [email protected] |
Supplier details are stated by each supplier. Lemonergy has not checked stock or origin. Listing is free and does not affect how products are ranked.
Similar batteries
Compare it with these. Nearest in the library by kind, format, chemistry, capacity and specific energy.
- EVE Energy LF356L356.3 Ah LFP prismatic cell · 3.2 V · 183 Wh/kgView the page
- EVE Energy MB31314 Ah LFP prismatic cell · 3.2 V · 179 Wh/kgView the page
- EVE Energy LF280280 Ah LFP prismatic cell · 3.2 V · 172 Wh/kgView the page
- EVE Energy LF304304 Ah LFP prismatic cell · 3.2 V · 179 Wh/kgView the page
- CATL 001CB0Y0310 Ah LFP prismatic cell · 3.2 V · 187 Wh/kgView the page
- CATL CB310280 Ah LFP prismatic cell · 3.2 V · 168 Wh/kgView the page