 "schema_version": 1,
 "dataset": "tongji-2022-ncm-nca",
 "title": "Tongji/KIT 18650 cycling dataset, Dataset_3 (NCM+NCA battery)",
 "publisher": "Tongji University / Karlsruhe Institute of Technology",
 "citation": "Zhu, J., Wang, Y., Huang, Y. et al. Data-driven capacity estimation of commercial lithium-ion batteries from voltage relaxation. Nature Communications 13, 2261 (2022). doi:10.1038/s41467-022-29837-w",
 "doi": "10.5281/zenodo.6405084",
 "landing": "https://zenodo.org/records/6405084",
 "license": "CC BY 4.0",
 "license_url": "https://creativecommons.org/licenses/by/4.0/",
 "license_evidence": "Zenodo record 6405084, 'Creative Commons Attribution 4.0 International' (API metadata license id cc-by-4.0), checked 2026-11-11",
 "attribution": "Data: Zhu, J., Wang, Y., Huang, Y. et al., Tongji University / Karlsruhe Institute of Technology, Dataset_3 (NCM+NCA battery), doi:10.5281/zenodo.6405084, CC BY 4.0. Per-cycle values computed by Lemonergy (battery-data).",
 "redistributable": true,
 "retrieved_at": "2026-11-11",
 "product_uid": "cell/maker-not-stated/tongji-kit-dataset-3-ncm-nca",
 "cells": {
  "maker": "not stated",
  "model": "not stated",
  "format": "18650 (the record: 'commercial 18650 type batteries')",
  "chemistry": "NCM+NCA (as the record names the set)",
  "nominal_capacity_ah": null,
  "count": 9
 },
 "batches": {
  "CY25-05_1": "3 cells (#1, #2, #3), 25 C, charge 0.5C / discharge 1C, as the file names state; the record states no reference capacity for the C-rates",
  "CY25-05_2": "3 cells (#1, #2, #3), 25 C, charge 0.5C / discharge 2C, as the file names state; the record states no reference capacity for the C-rates",
  "CY25-05_4": "3 cells (#1, #2, #3), 25 C, charge 0.5C / discharge 4C, as the file names state; the record states no reference capacity for the C-rates"
 },
 "archive": {
  "name": "Dataset_3_NCM_NCA_battery.zip",
  "bytes": 356066478,
  "md5": "d11e68e410a638058906af5e2f5f60f3",
  "md5_note": "matches the md5 Zenodo lists for the file"
 },
 "source_files": [
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_1-#1.csv",
   "bytes": 154123654,
   "sha256": "7abd6a620527377d4ec6b76857db386715a2bf8c188bd2da3179520a5532336f",
   "cycles": 941,
   "batch": "CY25-05_1",
   "file_cycles": 941
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_1-#2.csv",
   "bytes": 144504692,
   "sha256": "7292a08d5398cc31158c25e4b6c50a0cbd3aecfdde6924fb6bb4072a3efc4dac",
   "cycles": 960,
   "batch": "CY25-05_1",
   "file_cycles": 960
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_1-#3.csv",
   "bytes": 149890896,
   "sha256": "47f8aae27bf6efab688b42ee4474bed652e254cbc4aa8d144e91c142a9d66843",
   "cycles": 999,
   "batch": "CY25-05_1",
   "file_cycles": 999
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_2-#1.csv",
   "bytes": 145971800,
   "sha256": "e15c6f95dfe9aa17877df78f369e9ecab169b76dcf1f225ada16def0e2f12c23",
   "cycles": 984,
   "batch": "CY25-05_2",
   "file_cycles": 984
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_2-#2.csv",
   "bytes": 133893440,
   "sha256": "e6750c80c5fe0b4b5dcb6a93dcd505484e8a090a2a1af11e7a54428e39f6c6d6",
   "cycles": 963,
   "batch": "CY25-05_2",
   "file_cycles": 964,
   "repairs": [
    {
     "time_restart_at_row": 247348,
     "from_s": 3126881.39013171,
     "to_s": -21660.59625937609,
     "reason": "time runs backwards: a second recording, joined end to end; real gap unknown"
    }
   ]
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_2-#3.csv",
   "bytes": 155706621,
   "sha256": "8602584f31c729682b89d6e1ac37760b9fa43803fdfe84df58b925fd1cfd118e",
   "cycles": 1031,
   "batch": "CY25-05_2",
   "file_cycles": 1032,
   "repairs": [
    {
     "time_restart_at_row": 247631,
     "from_s": 3132136.351229682,
     "to_s": -21699.820263467496,
     "reason": "time runs backwards: a second recording, joined end to end; real gap unknown"
    }
   ]
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_4-#1.csv",
   "bytes": 134263298,
   "sha256": "866dfc9b03d7225a098a9fd57757f13f563da97d30bdc4bae83e4c148927d71b",
   "cycles": 992,
   "batch": "CY25-05_4",
   "file_cycles": 992,
   "recording_gaps": [
    {
     "after_s": 15968946.8,
     "length_s": 107014.7
    }
   ]
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_4-#2.csv",
   "bytes": 131334725,
   "sha256": "6952d7b083f5583d495c35dbd68c21b8d2677fa04b9a6e467b76486527eb4778",
   "cycles": 982,
   "batch": "CY25-05_4",
   "file_cycles": 982,
   "recording_gaps": [
    {
     "after_s": 15793164.2,
     "length_s": 102305.5
    }
   ],
   "repairs": [
    {
     "dropped_row": 1322578,
     "time_s": -247308.8705331404,
     "reason": "cell voltage 0 V or less: not a measurement"
    }
   ]
  },
  {
   "path": "Dataset_3_NCM_NCA_battery/CY25-05_4-#3.csv",
   "bytes": 131127465,
   "sha256": "3746256560179276fc9e528dc1b7dc699462cb68de589d4becb2d9a168216811",
   "cycles": 912,
   "batch": "CY25-05_4",
   "file_cycles": 912,
   "recording_gaps": [
    {
     "after_s": 4485005.8,
     "length_s": 98135.7
    },
    {
     "after_s": 15116795.7,
     "length_s": 7880.7
    }
   ]
  }
 ],
 "method": "Each CSV read straight from Dataset_3_NCM_NCA_battery.zip (no extraction) with battery-data tools/convert_tongji_csv.py, which maps it to BDF names and computes its cycles with tools/dataset_cycles.py: the conventions and cycle summary of tools/cyclers.py (current sign detected from the capacity columns; cycle = one charge followed by one discharge; capacity integrated from current with the cyclers integration rule 'right_rectangle_boundary': each sample's current over the interval before it, the first sample of a cycle included (the interval from the previous cycle's last sample), docs/32; nothing integrated across a recording gap longer than max(20 median sample intervals, 1 h)). The file's own cycle number and per-cycle counters are carried beside the computed values. Values are rounded as printed: Ah to 5 decimals, efficiency and volts to 4, seconds to 0.1. Regenerated on 13 November 2026 at battery-data c05009600e68e8e61ff67577025de90c34955816 with --integration right_rectangle_boundary (first published 11 November 2026 with the rule then in cyclers, right_rectangle; the change and its effect are in docs/33).",
 "caveats": [
  "The record and its zips state no maker, no model, no nominal capacity or voltage and no voltage limits (the zips hold only the cell CSVs; the 'Short discription.txt' in the record's impedance zip covers the impedance files only). The cells are therefore filed under the library's placeholder maker as 'Tongji-KIT Dataset_3 NCM+NCA', the record's own folder name, and 'nominal_capacity_ah' is null, so the 1.5 x nominal plausibility check of tools/check_datasets.py does not apply to this folder. The voltage range the cells were cycled over is visible in v_max and v_min, not stated.",
  "Temperatures and charge/discharge C-rates come from the file names (CYX-Y_Z-#N), as the record describes them; the capacity a C-rate refers to is not stated.",
  "Current sign: detected from the files' own capacity columns (charge positive); the 'Q charge' and 'Q discharge' counters restart within each file cycle.",
  "Integrated against reported capacity, over cycles where file cycle and computed cycle match one to one and the reported value exceeds 0.05 Ah: discharge median 0.000 mAh (95th percentile 0.000 mAh, max 1545.9 mAh; 8760 of 8762 within 10 mAh); charge median 0.000 mAh (95th percentile 0.000 mAh, max 826.7 mAh; 8761 of 8762 within 10 mAh), at the 5 printed decimals. The maxima are the odd cycles named below.",
  "Integration rule: right_rectangle_boundary (tools/cyclers.py, docs/32). The tester's 'Q charge' and 'Q discharge' columns are themselves the right-rectangle sum of the logged samples (EC-Lab's arithmetic, not a separate hardware integral), so this rule reproduces them. Until 13 November 2026 the values were computed with right_rectangle, which gave each cycle's first sample no time interval; here that sample is already charging at 0.5C with 10 s logging, so every charge was 3.47 mAh (1.25 A x 10 s, about 0.15 %) under the counter. Regenerating added that interval back: charge_ah rose by 3.47-3.49 mAh in 8,755 of 8,764 rows, discharge_ah did not change (docs/33).",
  "About every 100th file cycle of every cell is a long cycle of 3 to 4 days (a rest of up to about 87 h after the discharge); in the CY25-05_4 cells it also ends with a few seconds at about 5 A from about 2.43 V, which is why their v_min is below 2.5 V there. These cycles are kept as recorded; their discharge is not one at the batch's discharge rate.",
  "3 cells (CY25-05_4-#1, CY25-05_4-#2, CY25-05_4-#3) have recording gaps longer than an hour with current flowing after them (lengths per file under recording_gaps). Nothing is integrated across a gap. Across every one of these gaps the tester's own Q counters change, and in most the cell voltage too (for example Dataset_1 CY45-05_1-#17: 4.200 V before, 3.911 V after), so current flowed while nothing was logged; how much cannot be read reliably from the counters. The cycles around a gap therefore hold less charge or discharge than the cell saw. Where the interruption falls inside a file cycle the cycle is split in two and labelled '(split)'.",
  "CY25-05_2-#2: the clock runs backwards at CSV row 247348 (3126881.4 s to -21660.6 s): the file holds a second recording. It is joined end to end one sample interval after the first, so the real gap is unknown, and its file cycles are labelled 'run 2'.",
  "CY25-05_2-#3: the clock runs backwards at CSV row 247631 (3132136.4 s to -21699.8 s): the file holds a second recording. It is joined end to end one sample interval after the first, so the real gap is unknown, and its file cycles are labelled 'run 2'.",
  "CY25-05_4-#2: CSV row 1322578 (time -247308.9 s, cell voltage 0 V, current 0) is not a measurement and was dropped.",
  "Odd cycles are kept as recorded. Cycles whose integrated and reported capacity differ by more than 10 mAh: CY25-05_4-#1 cycle 911 discharge_ah 0.0 vs 1.5459; CY25-05_4-#2 cycle 905 charge_ah 0.86085 vs 1.68755; CY25-05_4-#3 cycle 867 discharge_ah 0.0 vs 1.52766. Each lies next to a recording gap or an unlogged start of charge (the first logged sample of the charge already shows charge on the tester's counter). Cycles with no single reported figure: CY25-05_2-#2 cycle 200; CY25-05_2-#3 cycle 200.",
  "Spot-checked by hand against the raw CSVs, integrating each file cycle independently: Dataset_1 CY25-025_1-#1 (cycles 1, 299) and CY25-1_1-#2 (four cycles), Dataset_2 CY35-05_1-#3 (four cycles), Dataset_3 CY25-05_4-#3 (four cycles). Discharge, v_max and v_min agree to the last printed digit or within 0.01 mAh; charge within 0.08 mAh in Dataset_1 and 2, and, in Dataset_3, 3.47 mAh low under the rule used before 13 November 2026 (see the integration caveat)."
 ],
 "columns": {
  "batch": {
   "unit": null,
   "meaning": "test condition from the file name, CYX-Y_Z: X temperature in C, Y_Z charge_discharge rate in C ('025' = 0.25, '05' = 0.5)"
  },
  "cell": {
   "unit": null,
   "meaning": "cell file name without .csv"
  },
  "cycle": {
   "unit": null,
   "meaning": "cycle number, 1-based, counted by battery-data (one charge followed by one discharge)"
  },
  "label": {
   "unit": null,
   "meaning": "the file's own 'cycle number' for the cycle; 'run 2' marks the second recording of a file whose clock restarts; '(split)' a file cycle that a recording interruption split in two"
  },
  "charge_ah": {
   "unit": "Ah",
   "meaning": "charge capacity integrated from current"
  },
  "discharge_ah": {
   "unit": "Ah",
   "meaning": "discharge capacity integrated from current"
  },
  "charge_ah_reported": {
   "unit": "Ah",
   "meaning": "largest 'Q charge' of the file cycle, in Ah; blank unless file cycle and computed cycle match one to one"
  },
  "discharge_ah_reported": {
   "unit": "Ah",
   "meaning": "largest 'Q discharge' of the file cycle, in Ah; blank unless file cycle and computed cycle match one to one"
  },
  "coulombic_efficiency": {
   "unit": null,
   "meaning": "discharge_ah / charge_ah (blank when charge_ah is zero)"
  },
  "v_max": {
   "unit": "V",
   "meaning": "highest cell voltage in the cycle"
  },
  "v_min": {
   "unit": "V",
   "meaning": "lowest cell voltage in the cycle"
  },
  "duration_s": {
   "unit": "s",
   "meaning": "length of the cycle"
  },
  "start_test_time_s": {
   "unit": "s",
   "meaning": "start of the cycle on the file's time axis (made continuous where the file's clock restarts)"
  }
 },
 "files": {
  "cycles.csv": {
   "rows": 8764,
   "sha256": "88c4995267e66dbc22a1f86d32cbc3f16dcd79bc2ea9d8d491a369cda8ce4897"
  }
 },
 "integration": {
  "rule": "right_rectangle_boundary",
  "computed_at": "c05009600e68e8e61ff67577025de90c34955816",
  "previous_rule": "right_rectangle",
  "docs": "docs/32-integration-rule.md, docs/33-regenerated-calce-tongji3-2026-11.md"
 }
}